Elardus, mostly in the servauth class. See SYS1.SAMPLIB(CEASEC). 

Barbara, also check out OA36024 

Just an additional note...CEA.CEAPDWB* as specified in CEASEC did not work for 
us. We had to use CEA.CEAPDWB 

Mary Anne 

On Tue, 8 Jan 2013 06:21:10 -0600, Elardus Engelbrecht 
<[email protected]> wrote:

>Mary Anne Matyaz wrote:
>
>>X'xxxx032D'   Client not authorized for instrumentation       Ensure user has 
>>access to instrumentation facilities.   CEANOINSTRAUTH
>
>Thanks, now I learned something new and useful.  ;-D
>
>Question: What access are related to above message? Do you mean access in RACF 
>Class WBEM? Or is it something else?
>
>TIA!
>
>Groete / Greetings
>Elardus Engelbrecht
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to