On Tue, 22 Jan 2013 07:49:00 +0100, Barbara wrote:

>You've asked for it:
>         AMDSADMP IPL=D3390,VOLSER=xxxxxx,                             +
>               REUSEDS=ALWAYS,IPLEXIST=YES,                            +
>               DUMP=('DSP OF ASID(ALL) ALSO PAGETABLES OF DATASPACES   +
>               ALSO SP(ALL) IN ASID(ALL)                               +
>               ALSO HIGH VIRTUAL IN ASID(ALL)'),                       +
>               MINASID=ALL,                                            +
>               DDSPROMPT=NO,                                           +
>               OUTPUT=(Dyyyy,MVSR.SADMP),                              +
>               CONSOLE=SYSC
>         END

Gotta love that girl. Who else would have that on an AD/CD system - and know 
why ?.
I had a SADUMP taken a couple of weeks back so we could try to figure out a 
loop in TN3270 on some (new) 1.13 systems, and not others. Wasn't genned like 
that, let me tell ya ... ;-)

Shane ...

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN