*The MCT is only required for CICS monitoring records which have adictionary. CICS statistics SMF 110 records are fixed.*
David, I believe that DFH$MOLS requires a dictionary. Perhaps it's optional but I based my job on the IBM documentation. On Wed, May 27, 2020 at 4:02 PM David Crayford <[email protected]> wrote: > Wayne, > > The MCT is only required for CICS monitoring records which have a > dictionary. CICS statistics SMF 110 records are fixed. > > On 2020-05-27 11:54 AM, Wayne Bickerdike wrote: > > You'll need a CICS MCT entry (Monitor control table). > > > > Sample JCL: > > > > //DELIT EXEC PGM=IDCAMS > > //SYSIN DD * > > DELETE SYS.CICSTS54.CICS.MNDUPREC > > SET MAXCC=0 > > /* > > //SYSPRINT DD SYSOUT=A > > //MNDUP EXEC PGM=DFHMNDUP > > //STEPLIB DD DSN=SYS3.CICSTS54.CICS.SDFHLOAD,DISP=SHR > > //SYSUT4 DD DSN=SYS.CICSTS54.CICS.MNDUPREC,DISP=(NEW,CATLG), > > // UNIT=SYSDA,SPACE=(TRK,(1,1)) > > //SYSPRINT DD SYSOUT=A > > //SYSUDUMP DD DUMMY > > //SYSIN DD * > > MCT=WB > > SYSID=MVS1 > > GAPPLID=CICS54T > > SAPPLID=CICS54T > > DATE=2018316 > > TIME=000100 > > //SMFUNLD EXEC PGM=IFASMFDP > > //* INDD1 DD DSN=SYS1.MAN1,DISP=SHR,AMP=('BUFSP=65536') > > //INDD1 DD DSN=SYS6.SMFDATA.BACKUP(0),DISP=SHR > > // DD DSN=SYS6.SMFDATA.BACKUP(-1),DISP=SHR > > // DD DSN=SYS6.SMFDATA.BACKUP(-2),DISP=SHR > > //OUTDD1 DD DSN=&&TEMP,DISP=(NEW,PASS),SPACE=(CYL,(20,20)), > > // UNIT=SYSDA > > //SYSPRINT DD SYSOUT=A > > //SYSIN DD * > > INDD(INDD1,OPTIONS(DUMP)) > > OUTDD(OUTDD1,TYPE(110(1))) > > /* > > //* > > //DEL2 EXEC PGM=IDCAMS > > //SYSPRINT DD SYSOUT=A > > //SYSIN DD * > > DELETE USER.DFHMOLS.UNLOAD > > SET MAXCC=0 > > /* > > //PRNT EXEC PGM=DFH$MOLS > > //STEPLIB DD DSN=SYS1.USER.LOAD,DISP=SHR > > // DD DSN=SYS3.CICSTS54.CICS.SDFHLOAD,DISP=SHR > > //INPUT DD DSN=SYS.CICSTS54.CICS.MNDUPREC,DISP=SHR > > // DD DSN=&&TEMP,DISP=(OLD,DELETE),UNIT=SYSDA > > //SYSUT2 DD DSN=&&XPND,DISP=(NEW,PASS),UNIT=SYSDA, > > // SPACE=(CYL,(25,10)) > > //SYSUT4 DD DSN=USER.DFHMOLS.UNLOAD,DISP=(,CATLG), > > // UNIT=SYSDA,SPACE=(CYL,(25,10)) > > //SORTWK01 DD SPACE=(CYL,(5,1)),UNIT=SYSDA > > //SORTWK02 DD SPACE=(CYL,(5,1)),UNIT=SYSDA > > //SORTWK03 DD SPACE=(CYL,(5,1)),UNIT=SYSDA > > //SORTWK04 DD SPACE=(CYL,(5,1)),UNIT=SYSDA > > //SORTWK05 DD SPACE=(CYL,(5,1)),UNIT=SYSDA > > //SORTDIAG DD SYSOUT=A > > //SYSOUT DD SYSOUT=A > > //SYSPRINT DD SYSOUT=A > > //SYSABEND DD SYSOUT=A > > //SYSUDUMP DD SYSOUT=A > > //SYSIN DD * > > OPTION LOCAL > > * > > RESOURCE ALL > > PRINT ALL > > UNLOAD > > > > Sample output lots of fields including USER ID:: > > > > > > ********************************* TOP OF DATA > > ********************************** > > *** DFH$MOLS - CICS 7.1.0 - MONITORING DATA LISTING PROGRAM *** > DATE > > 2020 > > OPTION LOCAL > > > > * > > > > RESOURCE ALL > > > > PRINT ALL > > > > UNLOAD > > > > > ******************************************************************************** > > * SMF HEADER * TIME = 0:01:00.00 DATE = 2018/316 > SYSTEM-ID > > = MV > > * * REC TYPE = 110 REC SUBTYPE = 1 NO OF > > TRIPLETS = 2 > > * * PROD SECT OFFSET = 44 PROD SECT LENGTH = > 114 > > NU > > * * DATA SECT OFFSET = 158 DATA SECT LENGTH = > > 10218 NU > > > ******************************************************************************** > > * SMF PRODUCT SECTION * REC VERSION = 0710 REC MAINT IND = 0 > G-APPLID > > = CI > > * * JOB NAME = ENTRY DATE = 2019/005 > > ENTRY TI > > * * 1ST CONN. OFFSET = 0 CONNECTOR LENGTH = 0 > > NU > > * * 1ST DATA OFFSET = 158 DATA ROW LENGTH = 26 > > NU > > * * COMPRESSED DATA LENGTH = 0 > > > > * * LOCAL TIME ZONE = 00000D69 LEAP SECOND OFFSET > = > > 00000 > > > ******************************************************************************** > > > > > > FIELD-NAME SIZE CONNECTOR OFFSET NICKNAME > NEW > > IN-COR > > > > > > DFHTASK C001 4 X'0001' X'0000' TRAN > > > > DFHTERM C002 4 X'0002' X'0004' TERM > > > > DFHCICS C089 8 X'0003' X'0008' USERID > > > > DFHTASK C004 4 X'0004' X'0010' TTYPE > > > > DFHCICS T005 8 X'0005' X'0014' START > > > > DFHCICS T006 8 X'0006' X'001C' STOP > > > > DFHTASK P031 4 X'0007' X'0024' TRANNUM > > > > DFHTASK A109 4 X'0008' X'0028' TRANPRI > > > > DFHTASK C166 8 X'0009' X'002C' TCLSNAME > > > > DFHTERM C111 8 X'000A' X'0034' LUNAME > > > > DFHPROG C071 8 X'000B' X'003C' PGMNAME > > > > DFHTASK C097 20 X'000C' X'0044' NETUOWPX > > > > DFHTASK C098 8 X'000D' X'0058' NETUOWSX > > > > DFHCICS C130 4 X'000E' X'FFFF' RSYSID > > > > > > On Wed, May 27, 2020 at 1:46 PM Wayne Bickerdike <[email protected]> > wrote: > > > >> CICS SMF 110. You could probably use DFH$MOLS to analyse, it takes some > of > >> the hard work out of breaking the SMF into readable stuff. > >> > >> On Wed, May 27, 2020 at 7:13 AM Matthew Stitt <[email protected] > > > >> wrote: > >> > >>> CICS statistics. Make sure they are turned on. > >>> > >>> The CICS statistics are written as SMF 110 records. > >>> > >>> It is possible to analyze them using various tools. > >>> > >>>> toot toot> Check CBT file 529. You will also need CBT file 527 for a > >>> sub-program or two. > >>> > >>> Matthew > >>> > >>> On Tue, 26 May 2020 16:59:28 -0400, Bob Bridges <[email protected] > > > >>> wrote: > >>> > >>>> I'm not a CICS jock, but at many of the installations I've worked at > >>> I've had occasion to analyze a record of who used which CICS > transactions > >>> over the past weeks or years. The datasets have had varying formats, > but > >>> I've gradually come to believe that CICS must track such things and > keep a > >>> log somewhere. The alternative is to believe that every installation > >>> reinvents this useful wheel independently, which I'm inclined to doubt. > >>>> Now I'm at a new place, and the guy I take to be the local CICS > sysprog > >>> (but I may be mistaken) says he's not aware of such a function. Is > this > >>> something easy I can point out to him, or am I mistaken about it being > a > >>> feature available to all CICS installations? > >>>> For that matter, is it something I can maybe find myself, without even > >>> bothering him? > >>>> --- > >>>> Bob Bridges, [email protected], cell 336 382-7313 > >>>> > >>>> /* Be careful of your thoughts; they may become words at any moment. > >>> -Ira Gassen */ > >>> ---------------------------------------------------------------------- > >>> For IBM-MAIN subscribe / signoff / archive access instructions, > >>> send email to [email protected] with the message: INFO IBM-MAIN > >>> > >> > >> -- > >> Wayne V. Bickerdike > >> > >> > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > -- Wayne V. Bickerdike ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN