Whether or not your methodology involves copying libraries or zones, you have 
to be careful of everything. Every strategy has risks that you need to address.

There is no need to re-receive anything. You should, however, frequently 
receive the HOLDATA.


--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3

________________________________________
From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Bill Giannelli [[email protected]]
Sent: Thursday, June 11, 2020 12:40 PM
To: [email protected]
Subject: Re: Separate SMPe environments for maintenance levels

So I've been reviewing the options you all have so kindly shares zonecopy, 
zonemerge, zoneexport....and it seems obvious you need to be careful of the 
DDDEFs and renaming of datasets. If not careful you can really screw up and 
overlay one environment.
While simplistic and perhaps slightly more work.....I am wondering if one 
"safe" way is to simply re-receive and re-apply the maintenance on the next 
environment when needed?
thanks
Bill

----------------------------------------------------------------------