On Sat, 4 Jul 2020 15:11:54 -0500, Nguyen Dt wrote:
>I tried the option NOALIGN when assembling , and it is OK now.
>
>So it means that i should examine my assembling listing to check if variables
>are not separated by some bytes for the alignement ?
>When i put all the variable to Character type i don't have any aligment ...
>In my case i see the problem because the output is not as expected , but i
>guess that it can source of errors.
>
An explicit length indicator suppresses alignment, so you might
keep the intended use of fields clearee by using, e.g.:
DS FL4 (unaligned fullword)
rather than:
DS CL4 (used as if fullword)
But beware of "0" repition factor:
DS 0F Aligned! IIRC
DS 0C Unaligned.
DS FL0 ???
-- gil
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN