OK, based on advice here, we'll schedule an LPAR bounce at the next IPL. Thanks!

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Mark Jacobs
Sent: Wednesday, July 8, 2020 12:02 PM
To: [email protected]
Subject: (External):Re: Configuring a CP online [EXTERNAL]

CAUTION EXTERNAL EMAIL

Yes, the Image profile needs to be updated for number of CPs to be brought 
online during IPL.

Mark Jacobs

Sent from ProtonMail, Swiss-based encrypted email.

GPG Public Key - 
https://api.protonmail.ch/pks/lookup?op=get&[email protected]

‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐
On Wednesday, July 8, 2020 2:46 PM, Feller, Paul 
<[email protected]> wrote:

> If this CP is to be online from now on then update the lpar hardware profile 
> to insure that it will be there after any deactivate/activate of the lpar. In 
> the back of my mind I'm thinking during the IPL process the system looks at 
> the profile to see what number of CPs should be online. I could be wrong, but 
> I keep thinking I've run into the same situation and updating the profile 
> fixed the issue.
>
> Thanks..
>
> Paul Feller
> GTS Mainframe Technical Support
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [email protected] On Behalf 
> Of Jesse 1 Robinson
> Sent: Wednesday, July 08, 2020 1:33 PM
> To: [email protected]
> Subject: Configuring a CP online [EXTERNAL]
>
> We added a logical CP a while back via CF online. After the next IPL, it was 
> offline until we reissued the CF command. What do we have to do to make it 
> 'permanent'?
>
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office <===== NEW
> [email protected]mailto:[email protected]
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to