That FRR is for SMF, you might check to see if there has been an earlier
failure, for example message CSV430I in the syslog.  Does your code issue
SMFWTM etc?  Sounds like your STIMERM popped to catch a small timing
window, maybe for asynchronous processing by TCP/IP for your send() that
you say failed.  I'd start by determining what that send() actually did.

On Wed, Sep 23, 2020 at 2:15 AM Pierre Fichaud <[email protected]> wrote:

> The STIMERM is in my code.
> The FRR is inside IEEMB830,08/31/16,UA82681 at +9D4.
>
> Regards, Pierre.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to