On 2020-10-16 1:43 PM, Tom Conley wrote:
On 10/15/2020 10:19 PM, David Crayford wrote:
There's no need to install TASID. The ISPF ISRDDN utility has an ENQ
dialog and is shipped as part of ISPF. From any command line enter
DDLIST;ENQ.
The major advantage to TASID is that it has a switch which will give
you the GRS Star information so you can see the ENQ's for all the
systems in the SYSPLEX. That feature, unfortunately, was not included
in ISRDDN. ISRDDN will only show you local ENQ's.
Nice! If you have a requirement for TASID you should download it from
IBM and not the CBT tape https://www.ibm.com/support/pages/tasid-v521-tool.
Regards,
Tom Conley
----------------------------------------------------------------------