Wow - I haven't heard Teradata in a number of years.  Check to make sure your 
device addresses are still listed in IECIOSxx of SYS1.PARMLIB

MIH DEV=(xxxx-xxxx),TIME=nn:nn

Ken

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Prashant Joshi3
Sent: Thursday, January 07, 2021 1:18 PM
To: [email protected]
Subject: Network issue - device box status

Hello,

I have remote database (teradata) connected to mainframe using FICON channel 
(Type=dummy). Every time; there is a drop/glitch in network
(microseconds) my mainframe devices get boxed and solution is to shutdown task, 
recycle devices, sometime it force to recycle chipids.
Is there any way to increase network tolerance time to avoid device box status?


Thanks,
Prashant


----------------------------------------------------------------------