What was the format (recfm, blksize, lrecl, dsorg) of the zOS dataset that
you uploaded the CD copy to?

Andy.


On Mon, 19 Apr 2021, 10:04 Hilario Garcia, <libr...@gmail.com> wrote:

> Hello,
>
> Thank you very much for your answer. I had already tried the solution you
> recommended and it gave me the following problem:
>
> IEBCOPY  COPY      INDD=SYSUT1,OUTDD=SYSUT2         GENERATED STATEMENT
>
> IEB1128I *** COPYR1 (1ST PDSU PHYSICAL RECORD)
>
>   0094A0 FFF8  00000000 00000000 7FE40000 7FE00000  |        "U  "\  |
>
>   0094B0 0008  00CA6D0F 020018B0 00509000 00807FF8  |  _      &    "8|
>
>   0094C0 0018  3030200F 00007FF8 2721000F E5A20000  |      "8    Vs  |
>
>   0094D0 0028  22520000 0002006B 00DE0000 00800000  |       ,        |
>
>   0094E0 0038  01000B07 69300000 7F000000 80807FF8  |        "     "8|
>
>   0094F0 0048  00008800 0011F000 00006540 00007FE4  |  h   0       "U|
>
>   009500 0058  02000000 000094E8 00006570 0C000014  |      mY        |
>
>   009510 0068  00006568 00008800 00000000 00000000  |      h         |
>
>   009520 0078  00000000 16000400 0611F000 20007FF8  |          0   "8|
>
>   009530 0088  00000000 00000000 00000000 00000000  ||
>
>   009540 0098  00000000 00000000 00000000 00000000  ||
>
> IEB120I SYSUT1   VALIDATION ERROR
>
> IEB178I NOT AN IEBCOPY UNLOADED DATA SET - 1ST PHYSICAL RECORD NOT 64 BYTES
> LONG
> IEB1030I DDNAME SYSUT1   REFERS TO PDSU DATA SET ON VOLUME SSSSSS NAMED
> IBMUSER.
> IEB1030I DDNAME SYSUT2   REFERS TO PDS  DATA SET ON VOLUME SSSSSS NAMED
> IBMUSER.
> IEB166I NO MEMBERS LOADED TO DATA SET REFERENCED BY SYSUT2
>
> IEB151I JOB HAS TERMINATED WITH ERROR(S)
>
> IEB147I END OF JOB - 8 WAS HIGHEST SEVERITY CODE
>
>
> Do you recommend any other possible solution.
>
> Thank you very much in advance.
>
> Kind Regards
>
> Hilario
>
> El lun, 19 abr 2021 a las 10:29, Styles, Andy (ITS zPlatform Services) (<
> 000000d68f765d25-dmarc-requ...@listserv.ua.edu>) escribió:
>
> > Classification: Public
> >
> > I wonder if these are IEBCOPY unload format - that is, IEBCOPY from a PDS
> > to a PS.  It's been years since I had to deal with those, probably since
> I
> > installed products directly from a vendor tape (one of those round things
> > with the write-protect ring).
> >
> > IEBCOPY seems to create unload format dasd datasets (here, at least) as
> >
> > Organization  . . . : PS
> > Record format . . . : VS
> > Record length . . . : 32736
> > Block size  . . . . : 32740
> >
> > Worth uploading one of those files as binary and then using an IEBCOPY PS
> > to PDS to reload it?
> >
> > Andy Styles
> > z/Series System Programmer
> >
> > -----Original Message-----
> > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf
> > Of Hilario Garcia
> > Sent: 19 April 2021 06:42
> > To: IBM-MAIN@LISTSERV.UA.EDU
> > Subject: Fwd: Format PDS unloaded on an CD
> >
> > -- This email has reached the Bank via an external source --
> >
> >
> > ---------- Forwarded message ---------
> > De: Hilario Garcia <libr...@gmail.com>
> > Date: lun, 19 abr 2021 a las 7:40
> > Subject: Format PDS unloaded on an CD
> > To: <IBM-MAIN@listserv.ua.edu>
> >
> >
> > Hello,
> >
> > Thank you very much for your contributions.
> > I have done multiple tests with different utilities (XMIT, FTP, IND $
> FILE,
> > AMATERSE) and I have not been able to download them in a valid format.
> > Attached I send in hexadecimal format the beginning of one of the PDS
> > (loaded as FB, lrecl = 80) and it seems that at the beginning of the file
> > is the directory of a PDS partitioned file. If the file is loaded as FB
> and
> > 80 bytes long, you can see the code in EBCDIC format. The original file
> is
> > in format binary and I have loaded it in binary.
> >
> > I would appreciate your help in this regard.
> >
> > Thank you very much in advance.
> >
> > Kind Regards
> >
> > Hilario
> >
> >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email
> > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email
> > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> > Lloyds Banking Group plc. Registered Office: The Mound, Edinburgh EH1
> 1YZ.
> > Registered in Scotland no. SC95000. Telephone: 0131 225 4555.
> >
> > Lloyds Bank plc. Registered Office: 25 Gresham Street, London EC2V 7HN.
> > Registered in England and Wales no. 2065. Telephone 0207626 1500.
> >
> > Bank of Scotland plc. Registered Office: The Mound, Edinburgh EH1 1YZ.
> > Registered in Scotland no. SC327000. Telephone: 03457 801 801.
> >
> > Lloyds Bank Corporate Markets plc. Registered office: 25 Gresham Street,
> > London EC2V 7HN. Registered in England and Wales no. 10399850.
> >
> > Scottish Widows Schroder Personal Wealth Limited. Registered Office: 25
> > Gresham Street, London EC2V 7HN. Registered in England and Wales no.
> > 11722983.
> >
> > Lloyds Bank plc, Bank of Scotland plc and Lloyds Bank Corporate Markets
> > plc are authorised by the Prudential Regulation Authority and regulated
> by
> > the Financial Conduct Authority and Prudential Regulation Authority.
> >
> > Scottish Widows Schroder Personal Wealth Limited is authorised and
> > regulated by the Financial Conduct Authority.
> >
> > Lloyds Bank Corporate Markets Wertpapierhandelsbank GmbH is a
> wholly-owned
> > subsidiary of Lloyds Bank Corporate Markets plc. Lloyds Bank Corporate
> > Markets Wertpapierhandelsbank GmbH has its registered office at
> > Thurn-und-Taxis Platz 6, 60313 Frankfurt, Germany. The company is
> > registered with the Amtsgericht Frankfurt am Main, HRB 111650. Lloyds
> Bank
> > Corporate Markets Wertpapierhandelsbank GmbH is supervised by the
> > Bundesanstalt für Finanzdienstleistungsaufsicht.
> >
> > Halifax is a division of Bank of Scotland plc.
> >
> > HBOS plc. Registered Office: The Mound, Edinburgh EH1 1YZ. Registered in
> > Scotland no. SC218813.
> >
> >
> >
> > This e-mail (including any attachments) is private and confidential and
> > may contain privileged material. If you have received this e-mail in
> error,
> > please notify the sender and delete it (including any attachments)
> > immediately. You must not copy, distribute, disclose or use any of the
> > information in it or any attachments. Telephone calls may be monitored or
> > recorded.
> >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to