What was the format (recfm, blksize, lrecl, dsorg) of the zOS dataset that you uploaded the CD copy to?
Andy. On Mon, 19 Apr 2021, 10:04 Hilario Garcia, <libr...@gmail.com> wrote: > Hello, > > Thank you very much for your answer. I had already tried the solution you > recommended and it gave me the following problem: > > IEBCOPY COPY INDD=SYSUT1,OUTDD=SYSUT2 GENERATED STATEMENT > > IEB1128I *** COPYR1 (1ST PDSU PHYSICAL RECORD) > > 0094A0 FFF8 00000000 00000000 7FE40000 7FE00000 | "U "\ | > > 0094B0 0008 00CA6D0F 020018B0 00509000 00807FF8 | _ & "8| > > 0094C0 0018 3030200F 00007FF8 2721000F E5A20000 | "8 Vs | > > 0094D0 0028 22520000 0002006B 00DE0000 00800000 | , | > > 0094E0 0038 01000B07 69300000 7F000000 80807FF8 | " "8| > > 0094F0 0048 00008800 0011F000 00006540 00007FE4 | h 0 "U| > > 009500 0058 02000000 000094E8 00006570 0C000014 | mY | > > 009510 0068 00006568 00008800 00000000 00000000 | h | > > 009520 0078 00000000 16000400 0611F000 20007FF8 | 0 "8| > > 009530 0088 00000000 00000000 00000000 00000000 || > > 009540 0098 00000000 00000000 00000000 00000000 || > > IEB120I SYSUT1 VALIDATION ERROR > > IEB178I NOT AN IEBCOPY UNLOADED DATA SET - 1ST PHYSICAL RECORD NOT 64 BYTES > LONG > IEB1030I DDNAME SYSUT1 REFERS TO PDSU DATA SET ON VOLUME SSSSSS NAMED > IBMUSER. > IEB1030I DDNAME SYSUT2 REFERS TO PDS DATA SET ON VOLUME SSSSSS NAMED > IBMUSER. > IEB166I NO MEMBERS LOADED TO DATA SET REFERENCED BY SYSUT2 > > IEB151I JOB HAS TERMINATED WITH ERROR(S) > > IEB147I END OF JOB - 8 WAS HIGHEST SEVERITY CODE > > > Do you recommend any other possible solution. > > Thank you very much in advance. > > Kind Regards > > Hilario > > El lun, 19 abr 2021 a las 10:29, Styles, Andy (ITS zPlatform Services) (< > 000000d68f765d25-dmarc-requ...@listserv.ua.edu>) escribió: > > > Classification: Public > > > > I wonder if these are IEBCOPY unload format - that is, IEBCOPY from a PDS > > to a PS. It's been years since I had to deal with those, probably since > I > > installed products directly from a vendor tape (one of those round things > > with the write-protect ring). > > > > IEBCOPY seems to create unload format dasd datasets (here, at least) as > > > > Organization . . . : PS > > Record format . . . : VS > > Record length . . . : 32736 > > Block size . . . . : 32740 > > > > Worth uploading one of those files as binary and then using an IEBCOPY PS > > to PDS to reload it? > > > > Andy Styles > > z/Series System Programmer > > > > -----Original Message----- > > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf > > Of Hilario Garcia > > Sent: 19 April 2021 06:42 > > To: IBM-MAIN@LISTSERV.UA.EDU > > Subject: Fwd: Format PDS unloaded on an CD > > > > -- This email has reached the Bank via an external source -- > > > > > > ---------- Forwarded message --------- > > De: Hilario Garcia <libr...@gmail.com> > > Date: lun, 19 abr 2021 a las 7:40 > > Subject: Format PDS unloaded on an CD > > To: <IBM-MAIN@listserv.ua.edu> > > > > > > Hello, > > > > Thank you very much for your contributions. > > I have done multiple tests with different utilities (XMIT, FTP, IND $ > FILE, > > AMATERSE) and I have not been able to download them in a valid format. > > Attached I send in hexadecimal format the beginning of one of the PDS > > (loaded as FB, lrecl = 80) and it seems that at the beginning of the file > > is the directory of a PDS partitioned file. If the file is loaded as FB > and > > 80 bytes long, you can see the code in EBCDIC format. The original file > is > > in format binary and I have loaded it in binary. > > > > I would appreciate your help in this regard. > > > > Thank you very much in advance. > > > > Kind Regards > > > > Hilario > > > > > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, send > email > > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, send > email > > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > Lloyds Banking Group plc. Registered Office: The Mound, Edinburgh EH1 > 1YZ. > > Registered in Scotland no. SC95000. Telephone: 0131 225 4555. > > > > Lloyds Bank plc. Registered Office: 25 Gresham Street, London EC2V 7HN. > > Registered in England and Wales no. 2065. Telephone 0207626 1500. > > > > Bank of Scotland plc. Registered Office: The Mound, Edinburgh EH1 1YZ. > > Registered in Scotland no. SC327000. Telephone: 03457 801 801. > > > > Lloyds Bank Corporate Markets plc. Registered office: 25 Gresham Street, > > London EC2V 7HN. Registered in England and Wales no. 10399850. > > > > Scottish Widows Schroder Personal Wealth Limited. Registered Office: 25 > > Gresham Street, London EC2V 7HN. Registered in England and Wales no. > > 11722983. > > > > Lloyds Bank plc, Bank of Scotland plc and Lloyds Bank Corporate Markets > > plc are authorised by the Prudential Regulation Authority and regulated > by > > the Financial Conduct Authority and Prudential Regulation Authority. > > > > Scottish Widows Schroder Personal Wealth Limited is authorised and > > regulated by the Financial Conduct Authority. > > > > Lloyds Bank Corporate Markets Wertpapierhandelsbank GmbH is a > wholly-owned > > subsidiary of Lloyds Bank Corporate Markets plc. Lloyds Bank Corporate > > Markets Wertpapierhandelsbank GmbH has its registered office at > > Thurn-und-Taxis Platz 6, 60313 Frankfurt, Germany. The company is > > registered with the Amtsgericht Frankfurt am Main, HRB 111650. Lloyds > Bank > > Corporate Markets Wertpapierhandelsbank GmbH is supervised by the > > Bundesanstalt für Finanzdienstleistungsaufsicht. > > > > Halifax is a division of Bank of Scotland plc. > > > > HBOS plc. Registered Office: The Mound, Edinburgh EH1 1YZ. Registered in > > Scotland no. SC218813. > > > > > > > > This e-mail (including any attachments) is private and confidential and > > may contain privileged material. If you have received this e-mail in > error, > > please notify the sender and delete it (including any attachments) > > immediately. You must not copy, distribute, disclose or use any of the > > information in it or any attachments. Telephone calls may be monitored or > > recorded. > > > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN