Actually I believe we had a couple turn themselves loose inside the unit. Sent 
from my Verizon, Samsung Galaxy smartphone
-------- Original message --------From: Seymour J Metz <[email protected]> Date: 
4/25/21  5:13 PM  (GMT-05:00) To: [email protected] Subject: Re: Diagram 
of MVS Control Blocks Did you have returning cartridges dropped onhe 
floor?--Shmuel (Seymour J.) 
Metzhttp://mason.gmu.edu/~smetz3________________________________________From: 
IBM Mainframe Discussion List [[email protected]] on behalf of 
patrickfalcone7 [[email protected]]Sent: Sunday, 
April 25, 2021 2:29 PMTo: [email protected]: Re: Diagram of MVS 
Control BlocksHope you are well Shmuel. We had one at NVIP. I believe my first 
performance problem was related to slowness early on after the online came up. 
One of the files ended up on MSS and the first time through was delayed by 
waiting for back end staging to the 3350s, I believe we had 2 staging devices. 
Of course after staging things were, well, better. I still have one of those 
bullets laying around somewhere. I forget what process would run that would 
validate the bullets and make that wrapping noise. I had access to the hardware 
and was in the room when this kicked off. Kind of jumped the first time I heard 
it. Seems we had quite a variety and never thought to list it and IBM was 
on-site all the time. Miss those days a bit.Sorry for the traipse down lane but 
I've often wondered what the tape drive was called that had a front/top cover 
like a roll top desk. I think it was IBM.Sent from my Verizon, Samsung Galaxy 
smartphone-------- Original message --------From: Seymour J Metz 
<[email protected]> Date: 4/25/21  12:17 PM  (GMT-05:00) To: 
[email protected] Subject: Re: Diagram of MVS Control Blocks IBM uses 
both the term Mass Storage Facility and the term Mass Storage System. From IBM 
3850 Mass Storage System (MSS) Principles of Operation, GA32-0029-0 : "The IBM 
3850 Mass Storage System is made up of three physical components:    1. The IBM 
3851 Mass Storage Facility    2. The Staging Adapter (either the IBM 3830 Model 
3 or the ISC with Staging Adapter)    3. The IBM 3333 Disk Storage Control and 
IBM 3330 Modell, 2, or 11 Disk Storage Units. "--Shmuel (Seymour J.) 
Metzhttp://mason.gmu.edu/~smetz3________________________________________From: 
IBM Mainframe Discussion List [[email protected]] on behalf of David 
Spiegel [[email protected]]Sent: Sunday, April 25, 2021 9:20 AMTo: 
[email protected]: Re: Diagram of MVS Control Blocks*MSSOn 
2021-04-25 08:55, Seymour J Metz wrote:> 3850 MSF (3851, 3830 and connected 
3330-1, 3330-11 or 3350 staging drives)?>>> --> Shmuel (Seymour J.) 
Metz----------------------------------------------------------------------For 
IBM-MAIN subscribe / signoff / archive access instructions,send email to 
[email protected] with the message: INFO 
IBM-MAIN----------------------------------------------------------------------For
 IBM-MAIN subscribe / signoff / archive access instructions,send email to 
[email protected] with the message: INFO 
IBM-MAIN----------------------------------------------------------------------For
 IBM-MAIN subscribe / signoff / archive access instructions,send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to