I can't get CBTVIEW to work,  I get to the part where it tries to download the 
File001 and it fails, so I downloaded it to my workstation and uploaded it to 
the mainframe as a FB 80 9440 file and now I get a message that says build 
completed (then it pauses for about 60 seconds) and then I get:

IEC141I 013-18,IGG0191B,BRIANW,$SYSTEMS,CBT78000,1466,PROD04,             
BRIANW.FILEIDX.PDS(CBTINDEX)                                              
IRX0250E System abend code 013, reason code 00000024.                     
IRX0255E Abend in host command execio or address environment routine TSO. 
IEA995I SYMPTOM DUMP OUTPUT                                               
SYSTEM COMPLETION CODE=013  REASON CODE=00000018                          
 TIME=21.40.14  SEQ=37529  CPU=0000  ASID=00E0                            
 PSW AT TIME OF ERROR  075C1000   80E74598  ILC 2  INTC 0D                
   NO ACTIVE MODULE FOUND                                                 
   NAME=UNKNOWN                                                           
   DATA AT PSW  00E74592 - 4100302C  0A0D010D  A7E5014B                   
   AR/GR 0: 00AFBF84/00000000_00E748A0   1: 00000000/00AA2D94_A4013000    
         2: 00000000/00000000_00072250   3: 00000000/00000000_00E74874    
         4: 00000000/00000000_00AAA410   5: 00000000/00000000_00AAA7A4    
         6: 00000000/00000000_00AAA74C   7: 00000000/00000000_00AAA7A4    
         8: 00000000/00000000_00AAA76C   9: 00000000/00000000_00072280    
         A: 00000000/00000000_00F9D658   B: 00000000/00000000_7F515CE8    
         C: 00000000/00000000_00000008   D: 00000000/00000000_00AAA7A4    
         E: 00000000/00000000_80E73DF6   F: 00000000/00000000_00000018    
 END OF SYMPTOM DUMP                                                      
IRX0670E EXECIO error while trying to GET or PUT a record.                
***                                                                       

I agree with the s013-18 because the CBTINDEX member is not there to open, but 
so much of this is hidden behind the CBT rexx exec that I can't tell where it's 
failing.

I think that FILE001 being in ZIP format might be hurting this, but I think the 
CBT exec is supposed to unzip it first, but maybe I'm wrong.  Has anyone got 
this to work or should I just start debugging now?

----------------------------------------------------------------------