Thanks to some timely help from Peter Vels who suggested tracing the FTP 
routine, I was able to find the problem. At my site the "locsite fwfriendly" is 
required.  I still don't know why that is, but it has been that way at several 
of the site I manage as well, (but not all).  Changing that to be there (it was 
commented out in the CBT exec), made it work.

Thanks again to Peter for pointing the way.

Brian

On Sun, 2 May 2021 00:03:15 -0500, Brian Westerman 
<[email protected]> wrote:

>Please ignore this problem.  When I went back and read the instructions I saw 
>that I'm suppose to UNZIP FILE001 before I upload it in binary format to the 
>sequential dataset.  Once I did that it loaded okay.  
>
>Just goes to show you, read the instructions closely before you complain. :)
>
>Now I have to work on getting the FTP part to work because it's not as much 
>use without that, (except I do like that you can see the comments when you 
>select the entry). 
>
>Does anyone know how to turn DEBUG on to see what's going wrong with FTP?
>
>Brian
>
>
>On Sat, 1 May 2021 23:52:08 -0500, Brian Westerman 
><[email protected]> wrote:
>
>>I can't get CBTVIEW to work,  I get to the part where it tries to download 
>>the File001 and it fails, so I downloaded it to my workstation and uploaded 
>>it to the mainframe as a FB 80 9440 file and now I get a message that says 
>>build completed (then it pauses for about 60 seconds) and then I get:
>>
>>IEC141I 013-18,IGG0191B,BRIANW,$SYSTEMS,CBT78000,1466,PROD04,             
>>BRIANW.FILEIDX.PDS(CBTINDEX)                                              
>>IRX0250E System abend code 013, reason code 00000024.                     
>>IRX0255E Abend in host command execio or address environment routine TSO. 
>>IEA995I SYMPTOM DUMP OUTPUT                                               
>>SYSTEM COMPLETION CODE=013  REASON CODE=00000018                          
>> TIME=21.40.14  SEQ=37529  CPU=0000  ASID=00E0                            
>> PSW AT TIME OF ERROR  075C1000   80E74598  ILC 2  INTC 0D                
>>   NO ACTIVE MODULE FOUND                                                 
>>   NAME=UNKNOWN                                                           
>>   DATA AT PSW  00E74592 - 4100302C  0A0D010D  A7E5014B                   
>>   AR/GR 0: 00AFBF84/00000000_00E748A0   1: 00000000/00AA2D94_A4013000    
>>         2: 00000000/00000000_00072250   3: 00000000/00000000_00E74874    
>>         4: 00000000/00000000_00AAA410   5: 00000000/00000000_00AAA7A4    
>>         6: 00000000/00000000_00AAA74C   7: 00000000/00000000_00AAA7A4    
>>         8: 00000000/00000000_00AAA76C   9: 00000000/00000000_00072280    
>>         A: 00000000/00000000_00F9D658   B: 00000000/00000000_7F515CE8    
>>         C: 00000000/00000000_00000008   D: 00000000/00000000_00AAA7A4    
>>         E: 00000000/00000000_80E73DF6   F: 00000000/00000000_00000018    
>> END OF SYMPTOM DUMP                                                      
>>IRX0670E EXECIO error while trying to GET or PUT a record.                
>>***                                                                       
>>
>>I agree with the s013-18 because the CBTINDEX member is not there to open, 
>>but so much of this is hidden behind the CBT rexx exec that I can't tell 
>>where it's failing.
>>
>>I think that FILE001 being in ZIP format might be hurting this, but I think 
>>the CBT exec is supposed to unzip it first, but maybe I'm wrong.  Has anyone 
>>got this to work or should I just start debugging now?
>>
>>----------------------------------------------------------------------
>>For IBM-MAIN subscribe / signoff / archive access instructions,
>>send email to [email protected] with the message: INFO IBM-MAIN
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to