Why not do this in a usermod?
Scott

    On Monday, May 10, 2021, 2:25:47 PM EDT, Kurt Quackenbush 
<ku...@us.ibm.com> wrote:  
 
 On 5/10/2021 1:15 PM, David Spiegel wrote:

> I added a CLIST as part of a PTF.
> (This is not vendor software.)
> ++CLIST(ABCXYZ) ALIAS(XYZ) DISTLIB(ACLIST) SYSLIB(CLIST).
> PROC 0
> WRITE HI
> 
> When I ran the APPLY Job, the IEBCOPY Output showed
> COPY OUTDD=CLIST,INDD=SMPWRK6
>   S M=((A0000000,ABCXYZ,R))
> 
> Where does (the ALIAS) XYZ get copied to //CLIST?
> (It is there after the Job runs, but, there is no record of it in the 
> Job Output.)
After the IEBCOPY operation SMP/E creates the alias in the data set 
directly using the STOW data management macro.

Kurt Quackenbush -- IBM, SMP/E Development
Chuck Norris never uses CHECK when he applies PTFs.

----------------------------------------------------------------------