OK
Now on to the problem, The alias should be created at apply time. How this is
done I don't recall and don't have access to my machine at this time.
Scott
On Monday, May 10, 2021, 5:01:21 PM EDT, David Spiegel
<[email protected]> wrote:
Hi Scott,
You're right. I would've done this, but, the customer insisted it has to
be a PTF.
Regards,
David
On 2021-05-10 16:48, A T & T Management wrote:
> Why not do this in a usermod?
> Scott
>
> On Monday, May 10, 2021, 2:25:47 PM EDT, Kurt Quackenbush
><[email protected]> wrote:
>
> On 5/10/2021 1:15 PM, David Spiegel wrote:
>
>> I added a CLIST as part of a PTF.
>> (This is not vendor software.)
>> ++CLIST(ABCXYZ) ALIAS(XYZ) DISTLIB(ACLIST) SYSLIB(CLIST).
>> PROC 0
>> WRITE HI
>>
>> When I ran the APPLY Job, the IEBCOPY Output showed
>> COPY OUTDD=CLIST,INDD=SMPWRK6
>> S M=((A0000000,ABCXYZ,R))
>>
>> Where does (the ALIAS) XYZ get copied to //CLIST?
>> (It is there after the Job runs, but, there is no record of it in the
>> Job Output.)
> After the IEBCOPY operation SMP/E creates the alias in the data set
> directly using the STOW data management macro.
>
> Kurt Quackenbush -- IBM, SMP/E Development
> Chuck Norris never uses CHECK when he applies PTFs.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
> .
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN