Sorry, copied it badly. A=WAIT was specified and the SLIP command was
accepted.

On Wed, 14 Jul 2021 13:57:59 -0500 Carmen Vitullo <[email protected]> wrote:

:>I see a valid option for ACTION is wait

:>ACTION=WAIT not A+WAIT?

:>Carmen

:>On 7/14/2021 12:05 PM, Binyamin Dissen wrote:
:>> I am having an issue with a loop and would like a SADUMP at the time of
:>> failure (test system)

:>> I put in

:>>        SLIP SET,C=071,A+WAIT,END

:>> but the system continues after the 071

:>> Why might this happen?

:>> I did not see an option to WAIT should the condition occur.

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN