Sorry, copied it badly. A=WAIT was specified and the SLIP command was accepted.
On Wed, 14 Jul 2021 13:57:59 -0500 Carmen Vitullo <[email protected]> wrote: :>I see a valid option for ACTION is wait :>ACTION=WAIT not A+WAIT? :>Carmen :>On 7/14/2021 12:05 PM, Binyamin Dissen wrote: :>> I am having an issue with a loop and would like a SADUMP at the time of :>> failure (test system) :>> I put in :>> SLIP SET,C=071,A+WAIT,END :>> but the system continues after the 071 :>> Why might this happen? :>> I did not see an option to WAIT should the condition occur. -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN