5-star response
Lennie

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
Jim Mulder
Sent: 30 August 2021 18:11
To: [email protected]
Subject: Re: RENT binder option

  New York responds, courteously.

  On a test system, you may specify the undocumented
CsvSP252RoundUp    TRAPS name in DIAGxx.  For a module 
being loaded into subpool 252, that will round the length up to a 4K
multiple. 

Jim Mulder z/OS Diagnosis, Design, Development, Test  IBM Corp. 
Poughkeepsie NY


"IBM Mainframe Discussion List" <[email protected]> wrote on
08/30/2021 12:00:52 PM:

> From: "Paul Gilmartin" 
> <[email protected]>
> To: [email protected]
> Date: 08/30/2021 01:00 PM
> Subject: Re: RENT binder option
> Sent by: "IBM Mainframe Discussion List" <[email protected]>
> 
> On Mon, 30 Aug 2021 09:49:14 -0400, Jim Mulder wrote:
> 
> >  The behavior of loading RENT modules from authorized libraries into 
> >subpool 252 (key 0) is to prevent them from being modified by 
> >unauthorized programs.  That is intended to contribute to security.
> >
> It would be a courtesy, think of it as a lagniappe, to the customer 
> wanting to verify code implementation, to protect pages even partially 
> occupied by REFR code.
> 
> -- gil



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to