To All,
For SMF types 70-79 (RMF), RMF may create broken records because the volume
of data can't fit in 32K.
So there may be 2 or more "broken" records created.
I have an IBM sample file that has the original unbroken record split into
3 broken records.
The records are consecutive in the sample file.
But I am getting the records in my SMF exit and I must save the broken
records to put them together at a later time.
There doesn't seem to be a unique identifier in the product section
connecting the 3 records.
I will use the SMF type/subtype/date/time in the SMF header for now.
But the time in 100ths of seconds doesn't seem granular enough to me.
Can someone help me here ?
Thanks in advance, Pierre.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN