The obvious reason is DIAGxx has AUTOIPL statement with that address.
Maybe changed by SET command?  Otherwise all I can think of is PPRC maybe
can do this, but unlikely.

On Fri, Nov 5, 2021 at 11:43 AM Mark Jacobs <
[email protected]> wrote:

> One of out systems went into a wait state today and autoipl was attempted.
> It failed with this message (from the HMC Hardware Events log)
>
> A load failure occurred on logical partition XXXX because a device address
> control block (DACB) was not found. Unit address = 5810.
>
> That unit address is not in our IODF. A manual activation was needed to
> bring it back up. I'm just curious how/why this error occurred.
>
> Mark Jacobs
>
> Sent from [ProtonMail](https://protonmail.com), Swiss-based encrypted
> email.
>
> GPG Public Key -
> https://api.protonmail.ch/pks/lookup?op=get&[email protected]
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to