MVS used to store the registers in the TCB, but that's not GUPI, so even if 
z/OS still does there's no guaranty that a later release won't break it.

Type 6 runs disabled out of the SVCFLIH and can't hold locks.

________________________________________
From: IBM Mainframe Discussion List <[email protected]> on behalf of 
David Cole <[email protected]>
Sent: Friday, November 26, 2021 2:16 AM
To: [email protected]
Subject: Type 1 SVCs

I have an ancient question... It seems to me I should know this after
all these decades, but... I don't.

While a type-1 SVC is running, where is the resume state data
(registers, PSW, etc.) stashed?

Is it the same for type-6?

And while I'm at it, what are the differences between type-1 and
type-6 SVCs, anyway>

Thanks,

David Cole
[email protected] (personal)
[email protected] (business)
540-456-6518 (cell)

----------------------------------------------------------------------