On Tue, 30 Nov 2021 09:43:55 +0000, Neale Ferguson <[email protected]> wrote:


>It fails with:
>
>IDC3014I CATALOG ERROR
>IDC3009I ** VSAM CATALOG RETURN CODE IS 48 - REASON CODE IS IGG0CLAT-80
>
>I am unable to work out what IGG0CLAT-80 is or why it’s failing. I am unsure 
>why VOL is required anyway, wouldn’t the STORCLAS/DATACLAS let the system pick 
>for itself? Might that volume not have enough free space? I would’ve hoped 
>that the generated workflow would “just work” with the right parameters. So I 
>assume one of my parameter is wrong but I didn’t see anywhere I could plug in 
>a volume name into the workflow parameters.
>

80         Explanation: Define data set with extended format       
           information is not valid for a non-SMS data set.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to