On Tue, 30 Nov 2021 05:54:25 -0600, Dave Jousma <[email protected]> wrote:

>On Tue, 30 Nov 2021 09:43:55 +0000, Neale Ferguson <[email protected]> 
>wrote:
>
>
>>It fails with:
>>
>>IDC3014I CATALOG ERROR
>>IDC3009I ** VSAM CATALOG RETURN CODE IS 48 - REASON CODE IS IGG0CLAT-80
>>
>>I am unable to work out what IGG0CLAT-80 is or why it’s failing. I am unsure 
>>why VOL is required anyway, wouldn’t the STORCLAS/DATACLAS let the system 
>>pick for itself? Might that volume not have enough free space? I would’ve 
>>hoped that the generated workflow would “just work” with the right 
>>parameters. So I assume one of my parameter is wrong but I didn’t see 
>>anywhere I could plug in a volume name into the workflow parameters.
>>
>
>80         Explanation: Define data set with extended format       
>           information is not valid for a non-SMS data set.

Does your dataclass specify extended format?   Or reduce your dataset 
allocation to something less than 65K tracks and try it.

----------------------------------------------------------------------