> It was our Second ServerPac order (in late August).  Our first order
> did not build a product correctly in our June  order.
> 
> Here is the order info from our currently installed ServerPac 
> (customer name redacted)
> 
> U02298367 - Products - 2021-08-26 14.30.31
> Customer number: S#########
> IBM order number: 7312760536

First of all, I'm sorry to hear you've had troubles and frustrations.  In 
any case here's what I think happened.  It was a timing issue.  Java 8 FP 
35 PTF UI76675 closed on August 11 and that is what caused the z/OSMF 
server start up failure.  Eventually that PTF went PE, but not before your 
ServerPac order was built on or about August 26, so it included the 
subject PTF.  The fix, Java 8 FP 36 PTF UI77368, did not become available 
until September 29, so of course it was not included in your ServerPac.

My personal recommendation, after you complete the ServerPac install, is 
to get the latest HOLDDATA and run SMP/E REPORT ERRSYSMODS to see if any 
PEs were identified since your order was built, and then install fixing 
PTFs as appropriate.  Pretty sure the PTF UI76675 would have been 
identified as an unresolved PE in this case.

Kurt Quackenbush -- IBM, z/OS SMP/E and z/OSMF Software Management
Chuck Norris never uses CHECK when he applies PTFs.



----------------------------------------------------------------------