I'm not sure why you are setting &SYSR2 to &SYSR1, &SYSR1 resolves to
the IPL volume without setting it, many years ago I used &SYSR2 since we
had 2 sysres volumes, the indirect catalog pointed to &SYSR2 and was
resolved in IEASYM00 like
SYMDEF(&SYSR2 = 'SYSRES2') <- the real volser
so, do you have any catalog entries that still point to &SYSR2 but are
actually on sysrs1?
that would be the only reason I'd think you need to do this
Carmen
On 1/30/2022 10:41 PM, Peter wrote:
Hello
Below is my IEASYMxx
SYMDEF(&SYSR2='&SYSR1')
I have created a alternate res pack with the name OSRESB and the currently
running is OSRESA.
Already RES volume dataset are indirectly cataloged.
With new RES I have done all the cloning plus IPLtext and getting root
volumes copied.
Is there is any work needs to be done to get the new RES volume recognized
as part of Symbolics ?
Peter
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email [email protected] with the message: INFO IBM-MAIN
--
/I am not bound to win, but I am bound to be true. I am not bound to
succeed, but I am bound to live by the light that I have. I must stand
with anybody that stands right, and stand with him while he is right,
and part with him when he goes wrong. *Abraham Lincoln*/
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN