Just trying to understand what will be the impact to the system if it overflows ?
On Thu, Mar 31, 2022, 5:24 PM Pommier, Rex <[email protected]> wrote: > Hi Peter, > > Are you asking if these parameters can be tuned or are you asking if they > can be tuned on the fly? They can be tuned but I believe it takes an IPL > to do so. Each addition of "1" in the ESQA parm adds 64K to the ESQA so to > barely cover the expansion you could change the 160 to 185 and IPL. I > would ask "why", though. I'm guessing you have plenty of ECSA so expanding > SQA into CSA isn't hurting anything. I seem to remember a long time ago > that some people actually advocated setting the SQA very small and letting > the majority of SQA overflow into the CSA. I don't know if anybody does > that on purpose or not any more. > > Rex > > -----Original Message----- > From: IBM Mainframe Discussion List <[email protected]> On Behalf > Of Peter > Sent: Thursday, March 31, 2022 3:28 AM > To: [email protected] > Subject: [EXTERNAL] SQA overflow into CSA > > Hello > > One of our zOS system 2.4 message 'SQA overflow into CSA 1593k(RMF III). > Under MXI tool I can see ESQA shows a overflow value of 1593k. > > Current SQA value in IEASYS00 > > 12,160 > > CSA > > 2500,300000 > > Is it something I can retune the above parameter ? > > Peter > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email > to [email protected] with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > The information contained in this message is confidential, protected from > disclosure and may be legally privileged. If the reader of this message is > not the intended recipient or an employee or agent responsible for > delivering this message to the intended recipient, you are hereby notified > that any disclosure, distribution, copying, or any action taken or action > omitted in reliance on it, is strictly prohibited and may be unlawful. If > you have received this communication in error, please notify us immediately > by replying to this message and destroy the material in its entirety, > whether in electronic or hard copy format. Thank you. > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN