Just trying to understand what will be the impact to the system if it
overflows ?

On Thu, Mar 31, 2022, 5:24 PM Pommier, Rex <[email protected]> wrote:

> Hi Peter,
>
> Are you asking if these parameters can be tuned or are you asking if they
> can be tuned on the fly?    They can be tuned but I believe it takes an IPL
> to do so.  Each addition of "1" in the ESQA parm adds 64K to the ESQA so to
> barely cover the expansion you could change the 160 to 185 and IPL.  I
> would ask "why", though.  I'm guessing you have plenty of ECSA so expanding
> SQA into CSA isn't hurting anything.  I seem to remember a long time ago
> that some people actually advocated setting the SQA very small and letting
> the majority of SQA overflow into the CSA.  I don't know if anybody does
> that on purpose or not any more.
>
> Rex
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of Peter
> Sent: Thursday, March 31, 2022 3:28 AM
> To: [email protected]
> Subject: [EXTERNAL] SQA overflow into CSA
>
> Hello
>
> One of our zOS system 2.4 message 'SQA overflow into CSA 1593k(RMF III).
> Under MXI tool I can see ESQA shows a overflow value of 1593k.
>
> Current SQA value in IEASYS00
>
> 12,160
>
> CSA
>
> 2500,300000
>
> Is it something I can retune the above parameter ?
>
> Peter
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> The information contained in this message is confidential, protected from
> disclosure and may be legally privileged. If the reader of this message is
> not the intended recipient or an employee or agent responsible for
> delivering this message to the intended recipient, you are hereby notified
> that any disclosure, distribution, copying, or any action taken or action
> omitted in reliance on it, is strictly prohibited and may be unlawful. If
> you have received this communication in error, please notify us immediately
> by replying to this message and destroy the material in its entirety,
> whether in electronic or hard copy format. Thank you.
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to