Thank you.. found it here
<https://www.ibm.com/docs/en/zos/2.4.0?topic=attributes-storage-group-types>

On Thu, 26 May 2022 at 10:50, Nigel Morton <[email protected]> wrote:

> Colin, this is controlled by the storage group construct, not the storage
> class.
>
> On Thu, 26 May 2022 at 10:16, Colin Paice <[email protected]> wrote:
>
> > I found a problem where I had a job with two steps.
> > step 1 unterse a file to a temporary file
> > step 2 use DFDSS to "restore" from the untersed file.
> >
> > When the temporary file is in VIO, I get a message from DFDSS
> >
> > *ADR025E (001)-DEVSU(03), INPUT DEVICE TYPE IS INVALID FOR TASK*
> >
> > If I use a non VIO dataset it works.   (I guess ADRDSSU is not smart
> enough
> > to handle VIO)
> >
> > When I add STORCLAS=SCNOVIO to my temporary file it does not use VIO.
> >
> > Looking in the SMS books, I cannot see where the  STORCLAS says use VIO
> or
> > not.
> >
> > Does anyone know where the use of VIO or not is defined in SMS?
> >
> > Colin
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [email protected] with the message: INFO IBM-MAIN
> >
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN