Thank you.. found it here <https://www.ibm.com/docs/en/zos/2.4.0?topic=attributes-storage-group-types>
On Thu, 26 May 2022 at 10:50, Nigel Morton <[email protected]> wrote: > Colin, this is controlled by the storage group construct, not the storage > class. > > On Thu, 26 May 2022 at 10:16, Colin Paice <[email protected]> wrote: > > > I found a problem where I had a job with two steps. > > step 1 unterse a file to a temporary file > > step 2 use DFDSS to "restore" from the untersed file. > > > > When the temporary file is in VIO, I get a message from DFDSS > > > > *ADR025E (001)-DEVSU(03), INPUT DEVICE TYPE IS INVALID FOR TASK* > > > > If I use a non VIO dataset it works. (I guess ADRDSSU is not smart > enough > > to handle VIO) > > > > When I add STORCLAS=SCNOVIO to my temporary file it does not use VIO. > > > > Looking in the SMS books, I cannot see where the STORCLAS says use VIO > or > > not. > > > > Does anyone know where the use of VIO or not is defined in SMS? > > > > Colin > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] with the message: INFO IBM-MAIN > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN