I don’t remember the file number, but the cbttape has a program to delete a
file while ignoring enques.

ITschak

בתאריך יום ו׳, 27 במאי 2022 ב-15:29 מאת Carmen Vitullo <[email protected]
>:

>
>
> what works for me, *sometimes* is i attempt to rename that dataset first,
> to .old or something, then delete it.
>
> I get a warning message, I don't recall the exact message but ISPF
> eventually tell me I have the authority and allows the rename , eventual
> delete
> when I copy my SMP target SYSRES I use this JCL,
>
>  //STEP0001 EXEC PGM=ADRDSSU,REGION=0M
> //*
> //SYSOUT DD SYSOUT=*
>
> //SYSPRINT DD SYSOUT=*
>
> //* 2.4 RSU2111
>
> //SMPVOL DD UNIT=SYSALLDA,VOL=SER=&SMPVOL,DISP=SHR
>
> //SYSRES DD UNIT=SYSALLDA,VOL=SER=&VOLUME,DISP=SHR
>
> //*
>
> //SYSIN DD *
>
> COPY INDDNAME(SMPVOL),OUTDDNAME(SYSRES),PURGE
>
> also make sure your ACS routines bypass any SYSRES HLQ's
>
> Carmen Vitullo
>
>
>
> -----Original Message-----
>
> From: Francois <[email protected]>
> To: IBM-MAIN <[email protected]>
> Date: Friday, 27 May 2022 4:23 AM CDT
> Subject: data set deletion problem
>
> Hello mainframers,
>
> I'm having trouble deleting some data sets.
>
> In order to apply PTFs to a z/OS system, I copied a system volume. Here is
> the JCL used :
>
> //COPY1 EXEC PGM=ADRDSSU
> //SYSPRINT DD SYSOUT=*
> //SYSIN DD *
> COPY -
> DATASET ( INCLUDE( -
> ** -
> ) ) -
> OUTDYNAM(RDL233) -
> LOGINDYNAM(RDL230) -
> ALLDATA(*) ALLEXCP -
> PROCESS(SYS1,UNDEF) -
> TOLERATE(ENQF) -
> FORCE -
> RECATALOG(MASTER.CATALOG.TOLZOS25.ZOS230)
> /*
>
> Due to a bad ACS, some data sets were picked up by SMS and therefore
> copied to the wrong volume and cataloged in the wrong catalog.
> I can't delete them because there is a XCFAS ENQ on them. I tried to
> unallocate the linklist and stop LLA but the ENQ is still active. Then I
> tried to activate an empty linklist and restart LLA with GET_LIB_ENQ(NO)
> without better result.
>
> Here is the bad data sets info :
> General Data
> Management class . . : MCDFLT
> Storage class . . . : SCDFLT
> Volume serial . . . : NW7C55
> Device type . . . . : 3390
> Data class . . . . . : **None**
> Organization . . . : PS
> Record format . . . : U
>
> Here is the DELETE output :
> IKJ56225I DATA SET RECE230.LOG.CDS02 ALREADY IN USE, TRY LATER
> IKJ56225I DATA SET IS ALLOCATED TO ANOTHER JOB OR USER
> IEFA110I DATA SET CONTENTION
> DATA SET RECE230.LOG.CDS02 IN USE BY
> SYSNAME JOBNAME ASID
> RECV XCFAS 0006
> IDC0551I ** ENTRY RECE230.LOG.CDS02 NOT DELETED
> IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 8
>
> The original data sets are not cataloged.
> This is a monoplex test system.
>
> This is not a problem to applying my PTFs. I have corrected the ACS and
> copied these files again on the desired volume and in the desired catalog.
> But i don't understand why i can't remove this XCFAS ENQ...
>
> Does anyone have an idea please?
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
-- 

*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **|  *

*|* *Email**: [email protected] **|* *Mob**: +972 522 986404 **|*
*Skype**: ItschakMugzach **|* *Web**: www.Securiteam.co.il  **|*

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to