No, it implies no such thing. IDCAMS is not a TSO command. ADDRESS LINKMVS IDCAMS is legitimate, subject to authorization;ADDRESS LINKMVS DELETE, ADDRESS LINKMVS RENAME, etc., arenot.
-- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3 ________________________________________ From: IBM Mainframe Discussion List [[email protected]] on behalf of Paul Gilmartin [[email protected]] Sent: Wednesday, August 17, 2022 8:38 AM To: [email protected] Subject: Re: rexx and IDCAMS functions On Wed, 17 Aug 2022 03:57:48 +0000, Seymour J Metz wrote: >The TSO commands that front-end IDCAMS expect a CPPL; you need ADDRESS TSO.; > That would imply that: //STEP EXEC PGM=IDCAMS wouldn't work since it provides no CPPL. LINKMVS provides an interface compatible with EXEC PGM=. >________________________________________ >From: Paul Gilmartin >Sent: Tuesday, August 16, 2022 2:36 PM > >Is this something that can't be done with ADDRESS LINKMVS IDCAMS? -- gil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN