I think what I am having a challenge with is the STGADMN.IDC.DCOLLECT in 
Facility Class

The UACC is NONE but the ACL has   *  READ

The process creates the JCL Statements in ALLOC statements.  SYSIN will contain 
the DCOLLECT control card

Then it just does a LINKMVS  to SYS1.LINKLIB(IDCAMS)

Almost like what you would code in Batch JCL.

I was requested to make this work, If I had a choice I would definitely change 
it

Thanks 

 

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Walt Farrell
Sent: Thursday, August 18, 2022 7:52 AM
To: [email protected]
Subject: Re: rexx and IDCAMS functions

On Tue, 16 Aug 2022 19:49:16 -0700, Lizette Koehler <[email protected]> 
wrote:

>I am actually using LINKMVS  and that is getting the error
>
>I want my general user to be able to do things without knowing idcams

What, exactly, does your code do, Lizette? What are you invoking with LINKMVS, 
and what are you passing to it? What environment is your REXX exec running in?

--
Walt

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to