There may be multiple conflicting invocations with MF=E.

--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3

________________________________________
From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Binyamin Dissen [[email protected]]
Sent: Saturday, October 1, 2022 7:40 PM
To: [email protected]
Subject: IEAMSCHD defaulting PLISTVER

Had a strange bug in new code.

Code was sequenced with the IEAMSCHD MF=(E,label,COMPLETE)  before the
IEAMSCHD MF=(L,label)

But the area was at the minimum size, not accounting for the parameters on the
MF=E version. This lead to an overlay.

Specified  MAX and all is OK.

I thought that (some?) macroes of this form remember what was used on the MF=E
and use it for the MF=L. Perhaps my memory is bad.

--
Binyamin Dissen <[email protected]>
https://nam11.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.dissensoftware.com%2F&amp;data=05%7C01%7Csmetz3%40gmu.edu%7C8e818a2313a6484bcf2b08daa4066a6f%7C9e857255df574c47a0c00546460380cb%7C0%7C0%7C638002644737236262%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C&amp;sdata=WHOz00SC%2BuOCND%2FNRtgfoFaAwcyEdcJlSqlp17Z6h2g%3D&amp;reserved=0

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------