I actually know very little about ICHENITY. I have, however, always understood 
it to be a dangerous, use at last resort tool. Requiring rather detailed 
knowledge of the RACF database structure. Or, maybe I am thinking of the direct 
block update utility 😊

> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On
> Behalf Of Pierre Fichaud
> Sent: Wednesday, October 05, 2022 11:56 AM
> To: [email protected]
> Subject: Re: ICHEINTY - RACF interface
> 
> [EXTERNAL EMAIL]
> 
> I have an update.
> After an hour or so of juggling the various parameters for ICHEINTY, I got 
> this
> :
> 
> 20.26.08 JOB04490 *IRR401I 0C4 ABEND DURING RACF PROCESSING OF  236
>    236               ALTER REQUEST FOR ENTRY T22TST1
> 20.26.08 JOB04490  IRR401I 0C4 ABEND DURING RACF PROCESSING
> 
>  I couldn't get the macro to work with DATAMAP=NEW and RELEASE 1.8.
>  I let it default to 1.7 and played with the parameters.
> 
>     Now I have an abend but I got no SYSMDUMP nor a SYSUDUMP.
> 
>     My next step is to set a SLIP trap but I'm waiting to be APF-authorized 
> to do
> this.
> 
>     1) Why is it a guessing game as to which parameters apply ?
> 
>     2) The examples are always coded in non-rent assembler programs.
>          I code exclusively re-entrant, AMODE 31 and RMODE ANY.
>          I rarely see IBM examples where the code is re-entrant.
>          And I never see the flavor that I am using, in this case ICHEINTY 
> ALTER,
> TYPE='USR'.
>          Couldn't IBM use examples that work in 31-bit and are re-entrant ?
> 
>     3) There is probably something in the generated parameter list that is
> wrong or missing.
>          Unfortunately, there is no mapping for the ICHEINTY parameter list.
>          Can IBM supply a mapping if it exists.
>          The doc refers to fields at various offsets.
>          I have no idea what to do to fix this problem.
>          It's a guessing game - back to #1.
> Regards, Pierre.
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to