Once the DECB is built you can reuse it .

On Mon, 13 Mar 2023 09:10:14 -0400 Joseph Reichman <[email protected]>
wrote:

:>My question is when do issue the WRITE macro  when I have constructed a 
complete block or after every record 
:>
:>Thanks 
:>
:>> On Mar 13, 2023, at 8:52 AM, Seymour J Metz <[email protected]> wrote:
:>> 
:>> ?You don't need to write a large block but you do need to construct both a 
BDW and an RDW. The length in the RDW should be 5 (control character plus RDW) 
than the length of the text, and the lenght in the BDW should be 4 more than 
that..
:>> 
:>> 
:>> --
:>> Shmuel (Seymour J.) Metz
:>> http://mason.gmu.edu/~smetz3
:>> 
:>> ________________________________________
:>> From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Joseph Reichman [[email protected]]
:>> Sent: Monday, March 13, 2023 7:43 AM
:>> To: [email protected]
:>> Subject: Re: IEC036I 002-30 trying to write messages to snapx
:>> 
:>> I move the iread ( list version of read ) in constants area to the decb 
layout ?
:>> 
:>> with macrf=w do I have to build the block on my own ?
:>> What I am asking do I have to have a ds  cl882 and accumulate as many 
records as I can with 1 BDW and 1 or more RDW. I know this sounds like I’m 
making things  complicated but I didn’t make it so snap did by having macrf=W 
instead of qsam just asking
:>> 
:>>> On Mar 13, 2023, at 6:03 AM, Binyamin Dissen <[email protected]> 
wrote:
:>>> 
:>>> ?First of all, congrats on showing your code.
:>>> 
:>>> Probably due to the DECB not being properly initialized.
:>>> 
:>>> You need a READ with MF=L in your constant area and need to copy it top the
:>>> working storage copy.
:>>> 
:>>> 
:>>> IREAD        READ whatever,MF=L
:>>> LREAD       EQU    *-IREAD
:>>> 
:>>> 
:>>> 
:>>> 
:>>>                 MVC    DECB(LREAD),IREAD
:>>> 
:>>> 
:>>> 
:>>> 
:>>> On Sun, 12 Mar 2023 23:27:56 -0400 Joseph Reichman <[email protected]>
:>>> wrote:
:>>> 
:>>> :>Hi
:>>> :>
:>>> :>
:>>> :>
:>>> :>In my estate routine I have a number of messages where I determine psw
:>>> :>offset 64 bit registers
:>>> :>
:>>> :>
:>>> :>
:>>> :>I wto it however I would like to write it to the snap data set
:>>> :>
:>>> :>
:>>> :>
:>>> :>The DCB IS
:>>> :>
:>>> :>
:>>> :>
:>>> :>DRDMPDD  DCB   DDNAME=DBGRDUMP,DSORG=PS,RECFM=VBA,MACRF=(W),BLKSIZE=882X
:>>> :>
:>>> :>               ,LRECL=125,EXLST=*-*
:>>> :>
:>>> :>EXISTS   DC   AL1(EXLLASTE+EXLRJFCB)
:>>> :>
:>>> :>
:>>> :>
:>>> :>
:>>> :>
:>>> :>My write Is WRITE DECB,SF,DRDMPDD,(R9),'S',MF=E
:>>> :>
:>>> :>
:>>> :>
:>>> :>The data is the wto messages so I have a 2 byte length proceeding which I
:>>> :>expand for 4 for the RDW
:>>> :>
:>>> :>
:>>> :>
:>>> :>I place the list as the first parameter to my subroutine
:>>> :>
:>>> :>
:>>> :>
:>>> :>So the first parameter is a list of addresses which have a two byte 
length
:>>> :>prefix
:>>> :>
:>>> :>
:>>> :>
:>>> :>Here is the code
:>>> :>
:>>> :>
:>>> :>
:>>> :>         L     R7,PARMADDR
:>>> :>
:>>> :>         XR    R0,R0
:>>> :>
:>>> :>MESSLOOP DS    0H
:>>> :>
:>>> :>         L     R6,0(R7)
:>>> :>
:>>> :>         L     R6,0(,R6)
:>>> :>
:>>> :>         LTR   R6,R6
:>>> :>
:>>> :>         BZ    DOSNAP
:>>> :>
:>>> :>         TM    0(R6),X'80'
:>>> :>
:>>> :>         BO    LASTMESS
:>>> :>
:>>> :>         XC    WRITEWRK,WRITEWRK
:>>> :>
:>>> :>         MVC   WRITEWRK+2(2),0(R6)
:>>> :>
:>>> :>         MVI   WRITEWRK+4,X'40'
:>>> :>
:>>> :>         ICM   R10,B'0011',0(R6)
:>>> :>
:>>> :>         BCTR  R10,0
:>>> :>
:>>> :>         EX    R10,MVEWRK
:>>> :>
:>>> :>         LA    R9,WRITEWRK
:>>> :>
:>>> :>        WRITE DECB,SF,DRDMPDD,(R9),'S',MF=E
:>>> :>
:>>> :>        CHECK DECB
:>>> :>
:>>> :>        LA    R7,4(,R7)
:>>> :>
:>>> :>        B     MESSLOOP
:>>> :>
:>>> :>MVEWRK   MVC   WRITEWRK+5(0),2(R6)
:>>> :>
:>>> :>
:>>> :>
:>>> :>This is the message I am getting
:>>> :>
:>>> :>
:>>> :>
:>>> :>IEC036I 002-30,IGC0005E,JOER,ISPFLITE,DBGRDUMP,0AAB
:>>> :>
:>>> :>
:>>> :>
:>>> :>The return code 30 from abend 002 is what is listed below but doesn't 
seem
:>>> :>to match my case
:>>> :>
:>>> :>
:>>> :>
:>>> :>30 One of the following is true: . A READ macro was issued, but the 
length
:>>> :>calculated to be read was zero.
:>>> :>
:>>> :>. A PUT macro using move mode was issued for a format 'F', 'FB', or 'U' 
QSAM
:>>> :>data set, but the DCBLRECL field contained zero or a negative value
:>>> :>
:>>> :>
:>>> :>
:>>> :>----------------------------------------------------------------------
:>>> :>For IBM-MAIN subscribe / signoff / archive access instructions,
:>>> :>send email to [email protected] with the message: INFO IBM-MAIN
:>>> 
:>>> --
:>>> Binyamin Dissen <[email protected]>
:>>> 
https://nam11.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.dissensoftware.com%2F&data=05%7C01%7Csmetz3%40gmu.edu%7Ca5384b0b51bd47b8246608db23b83213%7C9e857255df574c47a0c00546460380cb%7C0%7C0%7C638143046240514940%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C&sdata=1GXHejiPW0r%2FVJ1HXT1ML7iuT276UrtX8j7M8wwnXIw%3D&reserved=0
:>>> 
:>>> Director, Dissen Software, Bar & Grill - Israel
:>>> 
:>>> ----------------------------------------------------------------------
:>>> For IBM-MAIN subscribe / signoff / archive access instructions,
:>>> send email to [email protected] with the message: INFO IBM-MAIN
:>> 
:>> ----------------------------------------------------------------------
:>> For IBM-MAIN subscribe / signoff / archive access instructions,
:>> send email to [email protected] with the message: INFO IBM-MAIN
:>> 
:>> ----------------------------------------------------------------------
:>> For IBM-MAIN subscribe / signoff / archive access instructions,
:>> send email to [email protected] with the message: INFO IBM-MAIN
:>
:>----------------------------------------------------------------------
:>For IBM-MAIN subscribe / signoff / archive access instructions,
:>send email to [email protected] with the message: INFO IBM-MAIN

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN