Got it thanks 

> On Mar 13, 2023, at 10:03 AM, Seymour J Metz <[email protected]> wrote:
> 
> If your longest message is 120 then you only need 129.
> 
> 
> --
> Shmuel (Seymour J.) Metz
> http://mason.gmu.edu/~smetz3
> 
> ________________________________________
> From: IBM Mainframe Discussion List [[email protected]] on behalf of 
> Joseph Reichman [[email protected]]
> Sent: Monday, March 13, 2023 9:40 AM
> To: [email protected]
> Subject: Re: IEC036I 002-30 trying to write messages to snapx
> 
> So MF=L ( in constant storage initializes the DECB) but I think I have to 
> build an entire block before I issue the WRITE macro not sure if I have more 
> than 882 bytes it may only be one block
> 
> Thank you
> 
>> On Mar 13, 2023, at 9:33 AM, Binyamin Dissen <[email protected]> 
>> wrote:
>> 
>> Once the DECB is built you can reuse it .
>> 
>> On Mon, 13 Mar 2023 09:10:14 -0400 Joseph Reichman <[email protected]>
>> wrote:
>> 
>> :>My question is when do issue the WRITE macro  when I have constructed a 
>> complete block or after every record
>> :>
>> :>Thanks
>> :>
>> :>> On Mar 13, 2023, at 8:52 AM, Seymour J Metz <[email protected]> wrote:
>> :>>
>> :>> ?You don't need to write a large block but you do need to construct both 
>> a BDW and an RDW. The length in the RDW should be 5 (control character plus 
>> RDW) than the length of the text, and the lenght in the BDW should be 4 more 
>> than that..
>> :>>
>> :>>
>> :>> --
>> :>> Shmuel (Seymour J.) Metz
>> :>> http://mason.gmu.edu/~smetz3
>> :>>
>> :>> ________________________________________
>> :>> From: IBM Mainframe Discussion List [[email protected]] on behalf 
>> of Joseph Reichman [[email protected]]
>> :>> Sent: Monday, March 13, 2023 7:43 AM
>> :>> To: [email protected]
>> :>> Subject: Re: IEC036I 002-30 trying to write messages to snapx
>> :>>
>> :>> I move the iread ( list version of read ) in constants area to the decb 
>> layout ?
>> :>>
>> :>> with macrf=w do I have to build the block on my own ?
>> :>> What I am asking do I have to have a ds  cl882 and accumulate as many 
>> records as I can with 1 BDW and 1 or more RDW. I know this sounds like I’m 
>> making things  complicated but I didn’t make it so snap did by having 
>> macrf=W instead of qsam just asking
>> :>>
>> :>>> On Mar 13, 2023, at 6:03 AM, Binyamin Dissen 
>> <[email protected]> wrote:
>> :>>>
>> :>>> ?First of all, congrats on showing your code.
>> :>>>
>> :>>> Probably due to the DECB not being properly initialized.
>> :>>>
>> :>>> You need a READ with MF=L in your constant area and need to copy it top 
>> the
>> :>>> working storage copy.
>> :>>>
>> :>>>
>> :>>> IREAD        READ whatever,MF=L
>> :>>> LREAD       EQU    *-IREAD
>> :>>>
>> :>>>
>> :>>>
>> :>>>
>> :>>>                 MVC    DECB(LREAD),IREAD
>> :>>>
>> :>>>
>> :>>>
>> :>>>
>> :>>> On Sun, 12 Mar 2023 23:27:56 -0400 Joseph Reichman 
>> <[email protected]>
>> :>>> wrote:
>> :>>>
>> :>>> :>Hi
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>In my estate routine I have a number of messages where I determine psw
>> :>>> :>offset 64 bit registers
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>I wto it however I would like to write it to the snap data set
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>The DCB IS
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>DRDMPDD  DCB   
>> DDNAME=DBGRDUMP,DSORG=PS,RECFM=VBA,MACRF=(W),BLKSIZE=882X
>> :>>> :>
>> :>>> :>               ,LRECL=125,EXLST=*-*
>> :>>> :>
>> :>>> :>EXISTS   DC   AL1(EXLLASTE+EXLRJFCB)
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>My write Is WRITE DECB,SF,DRDMPDD,(R9),'S',MF=E
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>The data is the wto messages so I have a 2 byte length proceeding 
>> which I
>> :>>> :>expand for 4 for the RDW
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>I place the list as the first parameter to my subroutine
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>So the first parameter is a list of addresses which have a two byte 
>> length
>> :>>> :>prefix
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>Here is the code
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>         L     R7,PARMADDR
>> :>>> :>
>> :>>> :>         XR    R0,R0
>> :>>> :>
>> :>>> :>MESSLOOP DS    0H
>> :>>> :>
>> :>>> :>         L     R6,0(R7)
>> :>>> :>
>> :>>> :>         L     R6,0(,R6)
>> :>>> :>
>> :>>> :>         LTR   R6,R6
>> :>>> :>
>> :>>> :>         BZ    DOSNAP
>> :>>> :>
>> :>>> :>         TM    0(R6),X'80'
>> :>>> :>
>> :>>> :>         BO    LASTMESS
>> :>>> :>
>> :>>> :>         XC    WRITEWRK,WRITEWRK
>> :>>> :>
>> :>>> :>         MVC   WRITEWRK+2(2),0(R6)
>> :>>> :>
>> :>>> :>         MVI   WRITEWRK+4,X'40'
>> :>>> :>
>> :>>> :>         ICM   R10,B'0011',0(R6)
>> :>>> :>
>> :>>> :>         BCTR  R10,0
>> :>>> :>
>> :>>> :>         EX    R10,MVEWRK
>> :>>> :>
>> :>>> :>         LA    R9,WRITEWRK
>> :>>> :>
>> :>>> :>        WRITE DECB,SF,DRDMPDD,(R9),'S',MF=E
>> :>>> :>
>> :>>> :>        CHECK DECB
>> :>>> :>
>> :>>> :>        LA    R7,4(,R7)
>> :>>> :>
>> :>>> :>        B     MESSLOOP
>> :>>> :>
>> :>>> :>MVEWRK   MVC   WRITEWRK+5(0),2(R6)
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>This is the message I am getting
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>IEC036I 002-30,IGC0005E,JOER,ISPFLITE,DBGRDUMP,0AAB
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>The return code 30 from abend 002 is what is listed below but doesn't 
>> seem
>> :>>> :>to match my case
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>30 One of the following is true: . A READ macro was issued, but the 
>> length
>> :>>> :>calculated to be read was zero.
>> :>>> :>
>> :>>> :>. A PUT macro using move mode was issued for a format 'F', 'FB', or 
>> 'U' QSAM
>> :>>> :>data set, but the DCBLRECL field contained zero or a negative value
>> :>>> :>
>> :>>> :>
>> :>>> :>
>> :>>> :>----------------------------------------------------------------------
>> :>>> :>For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>>> :>send email to [email protected] with the message: INFO IBM-MAIN
>> :>>>
>> :>>> --
>> :>>> Binyamin Dissen <[email protected]>
>> :>>> 
>> https://nam11.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.dissensoftware.com%2F&data=05%7C01%7Csmetz3%40gmu.edu%7Cf10d394ae8df44d7ccee08db23ca888c%7C9e857255df574c47a0c00546460380cb%7C0%7C0%7C638143125001271106%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C&sdata=zpawdRdP0LaFYebDxIvSnOslmC%2BRb0qdho04eXxeH7Q%3D&reserved=0
>> :>>>
>> :>>> Director, Dissen Software, Bar & Grill - Israel
>> :>>>
>> :>>> ----------------------------------------------------------------------
>> :>>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>>> send email to [email protected] with the message: INFO IBM-MAIN
>> :>>
>> :>> ----------------------------------------------------------------------
>> :>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>> send email to [email protected] with the message: INFO IBM-MAIN
>> :>>
>> :>> ----------------------------------------------------------------------
>> :>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>> send email to [email protected] with the message: INFO IBM-MAIN
>> :>
>> :>----------------------------------------------------------------------
>> :>For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>send email to [email protected] with the message: INFO IBM-MAIN
>> 
>> --
>> Binyamin Dissen <[email protected]>
>> http://secure-web.cisco.com/1xY8yMt6hxjgH93o-c7tIxy7PU0KxMn57cxUkA7HzS4vpYrK7kOh-yUcSTgi_ozjT6eH978-rhLUf77h5pbc_r_etZmGjOaBk9mA0ej_J5RIGkWCVkQvL3r-ERH8rc-DtnGDwSMo5QAyfH4XYEjC_oSpqBNhzKJ3C4Knd_bJrjkcXpue1_3PBBwQ9ekV-l37iwo5EKCXXFcnZvga0gNrtDVKjzInrjDCrWN8sBUhh6QNe99qBV3LWvAQYhngAGuH0qNZtDHlXmOlivvVIy2vld0N07ylGzlIhDcFd_HU_YLEEXJP_MK38dqBnd7qr0nLijR5Oml0A4nAAQvlVNp59LoiU7LBQZBG-SVttVVom7CA5Azb3WIawa--Wzxc2WTQA03I2lIhaA3cuowaGj6eNpVdVN-ZfD6SDWRJ_fTqktrM/http%3A%2F%2Fwww.dissensoftware.com
>> 
>> Director, Dissen Software, Bar & Grill - Israel
>> 
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to