A long time ago when I was working on a limit exit, for testing I would
run a small program that did a variable length getmain for below/above
the line, something like this:
GETMAIN VRC,LV=(16000000,32)
GETMAIN VRC,LV=(2000000000,32),LOC=ANY
... and then spit out the results. The idea was to avoid using any of
the storage control blocks and see what *really* came back. Maybe
there's something on the CBT Tape that would do similar.
On 5/26/2023 9:43 AM, Radoslaw Skorupka wrote:
W dniu 26.05.2023 o 16:39, Phil Smith III pisze:
FYI, Radoslaw, that was getting the "current values 'from inside' of
the task", to use your phrasing. So you could make this work.
That's what I understood. Thank you again for the help.
However my goal was rather to start, let's say CICS region or some job
(with no changes) and find out effective REGION/MEMLIMIT settings.
I was also pointed to some Mark Zelden's rexx utility which read the
same control blocks. (Thanks!)
However finally I found some new SMFLIM keyword, which should cause
message ...and maybe I'll find some time next Monday to try it.
Regards
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,