On Thu, 31 Aug 2023 11:58:23 -0400, Phil Smith III wrote:
> ...
>//SYSUT1 DD DSN=&HLQ..VVSH84C.SMPMCS
> ...
>STMT NO. MESSAGE
> ....
> 6 IEFC624I INCORRECT USE OF PERIOD IN THE DSN FIELD
>I understand the latter error (because the SET didn't happen),
> ...
I could find that behavior useful. I have at times expressed a wish
that undefined symbols be reported as JCL errors. So I need only
follow the symbol with a period and an error will (probably) result
if undefined. For example:
//SYSUT2 DD DSN=&NAME.,RECFM=VB
will result in a JCL error if NAME is unset, rather than naming a
temporary data set.
Are the statements numbered in the job log, or do you just need to guess?
--
gil
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN