Hi 

First, I want to apologize for spelling error for " detainee SDWAEC1" that
should be data name.

Just briefly looking at the SDWA SDWARC1 points to the control registers at
the time of error I guess I can interrogate 3 & 4 see if they are different
with control register 4 being primary. 

Still trying to figure out SDWAEC1 and SDWAEC2 

Where SDWAEC1 points to the PC instruction while SDWAEC2 points to the error
itself 

Thing is the recovery program executes in the home address space so it
possible the that primary address space could be gone.

Thank you.

    

     

_____________________________________________
From: [email protected] <[email protected]> 
Sent: Sunday, December 31, 2023 12:28 PM
To: 'IBM Mainframe Discussion List' <[email protected]>
Subject: Help Trying to determine where abend occurred 


Hi

I have a Space Switching PC routine which I caused an abend 

This the code that caused it

         LLILF 15,X'7FFFF000' 
         SVC 42               

I don't have a ARR covering it However I do a estate in the program that
issued PC Instruction to a space switching routine where the above two
instructions live

The PSW at offset X'78' of the SDWA points to the next  instruction AFTER
THE svc 42 it the  data name SDWAEC2

The SDWA at offset 68 detainee SDWAEC1 points to the instruction after the
pc instruction in the home address space 

My question is there any field in the SDWA or extensions that would tell me
in what ASID the abend occurred 


thanks       

----------------------------------------------------------------------