Yes, we have dedicated volser ranges and REJECTs.
However the RMM have to be active on every LPAR/image connected to the VTS. Otherwise the insert hangs up.

--
Radoslaw Skorupka
Lodz, Poland




W dniu 28.10.2024 o 20:24, Mike Schwab pisze:
A dedicated volser range.  TST??? from test LPAR only.

On Mon, Oct 28, 2024 at 11:09 AM Radoslaw Skorupka
<[email protected]> wrote:
The following scenario:
VTS system connected to multiple z/OS images, each system has it's own
volcat, RMM CDS, etc.
Issue: the RMM has to be active on every LPAR, otherwise there are
problems with volume insert process.
So, even sandbox system with no tape activity must have RMM active.

Q: Is there any method to not have active RMM on every system connected
to the VTS?

I guess it would be sufficient to disconnect the LPAR from the RMM (CF
CHP or VARY PATH OFFLINE), however I vaguely remain I did it in the old
times of 3494 and physical carts. Unfortunately I have no notes about it.

--
Radoslaw Skorupka
Lodz, Poland

----------------------------------------------------------------------