I have a business need to scan 15 different tape files (all the same record 
format, some are multi-volume) to extract relevant information, and I first 
tried to scan them all in one concatenated DD.  I didn't specify anything but 
DISP and DSN for each file in the concatenation, so I got 15 tape mounts to 15 
different tape drives.

I would like to limit the tape drive usage so as not to unintentionally 
interfere with production work that actually needs a tape drive.  Using 
UNIT=AFF=INPUTDD on the second and all other DD's in the concatenation limits 
usage to ONE tape drive, the one allocated to the first file in the 
concatenation.

In order to reduce elapsed time for the scan job (each tape dismount/mount 
operation takes an appreciable amount of time, usually at least a minute or 
so), is there any way to use TWO drives in one concatenated DD instead of one 
drive, so that as each file reaches EOF the process continues with the 
already-mounted next file while the system loads the EOF drive with the next 
file?  If I knew in advance the device numbers of tape drives that are actually 
available I could try to use UNIT=device1 and UNIT=device2 on alternating DD's, 
adding ",,DEFER" to all but the first two DD's, but I don't know what drives 
are available before I submit the job.

If there is a way to use two drives without knowing the device numbers ahead of 
time, what happens if one of the tape DD's is a file that has multiple volumes? 
 Does an already-mounted file from the next DD get dismounted to load the next 
volume of the one being processed, or does it dismount the first volume and 
wait for the next volume to be mounted on the same drive?

These aren't "real" drives of course, they are all in a VTL, but the principal 
is the same - don't occupy more devices than you really need.

Peter

This message and any attachments are intended only for the use of the addressee 
and may contain information that is privileged and confidential. If the reader 
of the message is not the intended recipient or an authorized representative of 
the intended recipient, you are hereby notified that any dissemination of this 
communication is strictly prohibited. If you have received this communication 
in error, please notify us immediately by e-mail and delete the message and any 
attachments from your system.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to