Why not use the z/OS UNIX "as" command?

It's described in the z/OS UNIX System Services Command Reference.

On 2025-02-05 13:11 PM, Binyamin Dissen wrote:
Don't understand most of the shell stuff, but ASMA90 is not a TSO command - it
is a program.

If invoked with multiple parameters (which it would be if invoked as a TSO
command), one of the parameters is overriding DDNAMEs.

There appears to be an AS command.

Also I would expect

tsocmd -d "call *(asma90)"

to work.



On Wed, 5 Feb 2025 16:01:11 +0000 David Frenzel
<[email protected]> wrote:

:>Hi,
:>
:>I am trying to execute the assembler ASMA90 with tsocmd from a shell script 
in USS. My shell script is simple:
:>#!/bin/sh
:>
:>export sysin="alloc dsname('IBMUSER.BMSPDSE(BMS)') shr reuse"
:>export TSOALLOC=sysin
:>
:>export syslin="alloc dsname('IBMUSER.PROG.OBJ') shr reuse"
:>export TSOALLOC=syslin:$TSOALLOC
:>
:>export sysprint="alloc dsname('IBMUSER.BMS.SYSPRINT') shr reuse"
:>export TSOALLOC=sysprint:$TSOALLOC
:>
:>export syspunch="alloc dsname('IBMUSER.PROG.OBJ') shr reuse"
:>export TSOALLOC=syspunch:$TSOALLOC
:>
:>export sysadata="alloc dsname('IBMUSER.PROG.ADATA') shr reuse"
:>export TSOALLOC=sysadata:$TSOALLOC
:>
:>export sysut1="alloc lrecl(80) recfm(f,b) new"
:>export TSOALLOC=sysut1:$TSOALLOC
:>
:>tsocmd -d "ASMA90"
:>
:>The SYSIN data set is an FB 80 PDSE which contains a member includes a BMS 
map. I am aware that I am missing more DDs and assembler parameters to assemble a 
BMS map.
:>I am stuck earlier, ASMA90 puts this on the SYSPRINT:
:>** ASMA413C Unable to open INPUT file
:>
:>
:>HIGH LEVEL ASSEMBLER - INTERRUPT AND DIAGNOSTIC DUMP
:>** ASMA935U One or more required files not available
:>
:>I can only assume SYSIN is meant with “INPUT file”. When I execute a JCL that 
allocates the same data set the assembler runs fine.
:>I can see some weird messages on the SYSLOG whenever I execute the script:
:>N 0020000 VS01     25036 11:55:08.15 STC00095 00000090  IEC130I BMUSER   DD 
STATEMENT MISSING
:>N 0020000 VS01     25036 11:55:08.15 STC00095 00000090  IEC130I UENU   I     
DD STATEMENT MISSING
:>
:>Any help is appreciated on a) what is causing the issue and/or b) why this 
behaves so differently compared to a JCL.
:>
:>Cheers – David
:>
:>[email protected]<mailto:[email protected]>

----------------------------------------------------------------------