Seymour its a LM R14,R12,12(R13) I think they did something with the system its was working last week
> On Feb 16, 2025, at 4:35 PM, Joseph Reichman <[email protected]> wrote: > > I posted the code > > There was nothing in this environment that had to do with Rexx > > I did it once from a clist > > And second time running test from the ready prompt > > Both times I got the 66D abend reason code 61 > > Thanks > >> On Feb 16, 2025, at 4:06 PM, Binyamin Dissen >> <[email protected]> wrote: >> >> What do you think the CAMLST macro does? >> >> What might be missing? >> >> On Sun, 16 Feb 2025 15:54:34 -0500 Joseph Reichman >> <[email protected]> wrote: >> >> :>? >> :>I’m not at home >> :> >> :>But I wrote a simple program and I remember it from memory >> :> >> :>TESTDS CSECT >> :>TESTDS AMODE 31 >> :>TESTDS RMODE ANY >> :> USING TESTDS,R3 >> :> LR R3,R15 >> :> LOCATE AB >> :>AB CAMLST NAME,DS,,LOCAREA >> :>DS DC CL44’MY.DATATEST’ >> :> DS 0D >> :>LOCAREA DS CL265 >> :> END >> :> >> :>I ran this under TEST >> :> >> :>Made a break point after the SVC 26 >> :> >> :>And that’s where I got the abend 66D reason 61 >> :> >> :>The text said “Unable to serialize or release serialization when accessing >> to tso/e data stack” >> :> >> :>The abend code was 66D reason code 61 >> :> >> :>Hope this explains things >> :> >> :>I think it has something to do with installation setup >> :> >> :>Thanks >> :>> On Feb 16, 2025, at 3:22?PM, Binyamin Dissen >> <[email protected]> wrote: >> :>> ?All together now: >> :>> >> :>> "Show the code" >> :>> >> :>> On Sun, 16 Feb 2025 12:42:34 -0500 Joseph Reichman >> :>> <[email protected]> wrote: >> :>> >> :>> :>Hi >> :>> :>Sorry about the previous post >> :>> :> >> :>> :>I fat finger it and didn’t now how to recall or delete >> :>> :> >> :>> :>Well here is my question >> :>> :> >> :>> :> >> :>> :>I am getting some strange abends fro LOCATE >> :>> :> >> :>> :>Specifically abend 66D reason code 61 >> :>> :> >> :>> :>I am running the program from a clist under TSO TEST >> :>> :> >> :>> :>My goal is to determine whether the dataset exists >> :>> :> >> :>> :>Just wondering is S99VRBIN using SVC 99 would be a better way >> :>> :> >> :>> :>And If so what text units should I use >> :>> :> >> :>> :>Thank you >> :>> :>---------------------------------------------------------------------- >> :>> :>For IBM-MAIN subscribe / signoff / archive access instructions, >> :>> :>send email to [email protected] with the message: INFO IBM-MAIN >> :>> >> :>> -- >> :>> Binyamin Dissen <[email protected]> >> :>> http://www.dissensoftware.com >> :>> >> :>> Director, Dissen Software, Bar & Grill - Israel >> :>> >> :>> ---------------------------------------------------------------------- >> :>> For IBM-MAIN subscribe / signoff / archive access instructions, >> :>> send email to [email protected] with the message: INFO IBM-MAIN >> :> >> :>---------------------------------------------------------------------- >> :>For IBM-MAIN subscribe / signoff / archive access instructions, >> :>send email to [email protected] with the message: INFO IBM-MAIN >> >> -- >> Binyamin Dissen <[email protected]> >> http://www.dissensoftware.com >> >> Director, Dissen Software, Bar & Grill - Israel >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN