Classification: Confidential HSEND LIST TTOC SELECT(BACKUP) ? on the syntex. Done forom memory. Check the fine manuals for proper syntax.
-----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Greg Peck Sent: Thursday, June 12, 2025 10:22 PM To: [email protected] Subject: How does HSM know its backup and spill volumes (VOLSERS)? [CAUTION: This Email is from outside the Organization. Unless you trust the sender, Don’t click links or open attachments as it may be a Phishing email, which can steal your Information and compromise your Computer.] Hi, I can list the defined BACKUP and SPILL volumes for our HSM system using these commands: TSO hsend q backup(daily) which returns the below as the last line of output ARC0164I DAY=01 VOLS = HSMTB2-A HSMTB1-F HSMTB0-A and TSO hsend q backup(spill) which returns the below as the last line of output ARC0164I SPILL VOLS = HSMTS0-F HSMTS2-A HSMTS1-A However, I can't seem to find where these volumes are made known to HSM - there are no obvious ADDVOL commands at startup time. Is this information possibly "hardened" somewhere (in one of the control datasets?) Or perhaps in an SMS construct? I used to know but as the years pass by, memory fades... Thanks! ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ::DISCLAIMER:: ________________________________ The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ________________________________ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
