Hi,

I can list the defined BACKUP and SPILL volumes for our HSM system using these 
commands:

TSO hsend q backup(daily)
which returns the below as the last line of output
ARC0164I DAY=01     VOLS = HSMTB2-A HSMTB1-F HSMTB0-A

and

TSO hsend q backup(spill)
which returns the below as the last line of output
ARC0164I SPILL      VOLS = HSMTS0-F HSMTS2-A HSMTS1-A

However, I can't seem to find where these volumes are made known to HSM - there 
are no obvious ADDVOL commands at startup time.

Is this information possibly "hardened" somewhere (in one of the control 
datasets?) Or perhaps in an SMS construct?

I used to know but as the years pass by, memory fades...

Thanks!

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
________________________________
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
________________________________

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to