Might be when(program) controlled Get Outlook for iOS<https://aka.ms/o0ukef> ________________________________ From: IBM Mainframe Discussion List <[email protected]> on behalf of Paul Gilmartin <[email protected]> Sent: Sunday, June 29, 2025 3:26:17 PM To: [email protected] <[email protected]> Subject: Re: [IBM-MAIN] APF authorized TSO programs
On Sun, 29 Jun 2025 17:01:07 -0500, Steve Beaver wrote: >Did you APF the STEPLIB > > >Sent from my iPhone > >No one said I could type with one thumb > And mark the program AC=1" Please, IBM,this isn't 1970 with storage capacity limitation. the diagnostic should indicate one or more of: o AC=0 o Not in AUTHLIST o data set not RACF autjorized o Other? Don't tease the customer with an exercise in enigmatology. (I suspect Joseph's employer prohibits posting excerpts that would enable this list to help him more.) >> On Jun 29, 2025, at 16:49, Joseph Reichman wrote: >> >> Hi >> >> I have any APF authorized program >> It’s in the STEPLIB ( and the only one in my steplib ) of my TSO logon PROC >> >> I have the program name in the AUTHPGM NAMES and AUTHCMD NAMES of my >> IKJTSOxx member in parmlib >> >> And yet I keep on getting 047 abend code >> >> Thanks -- gil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN