Under z/OS 1.13, the z/OS Unicode User's Guide and Reference, appendix A
says that the default tables include  direct (non-Unicode) conversions
between 1047 and 850 for techniques R,C and L.

But there is no SYS1.SCUNTBL(CUNLM0EB) and an attempt to load the
conversion table for 1047->850 with technique=L  fails:

Unable to initialize CUNLCNV. RC=8, Reason Code=3,
sourceCodePage="ibm-1047"(1047), targetCodePage="ibm-850"(850)

Is it just a documentation error?  (There is actually no supplied table for
1047->850 with technique=L)

It turns out that there IS a table for technique=M.

Kirk Wolf
Dovetailed Technologies
http://dovetail.com

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN