There are possibly differences in your catalogs compared to the driving system.
Use DDLIST to see what's allocated before/after failure.

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of venkat kulkarni
> Sent: Thursday, December 12, 2013 9:53 AM
> To: [email protected]
> Subject: Re: Server Pac Panel Issue
> 
> Yes. But I am still not able to find that, why the CPPCSAMP is not able to 
> find
> the library where the LMODs are located.
> 
> 
> 
> 
> On Thu, Dec 12, 2013 at 11:18 PM, Lizette Koehler
> <[email protected]>wrote:
> 
> > I think the recommendation to contact IBM may be the right way to go next.
> >
> > Lizette
> >
> >
> > > -----Original Message-----
> > > From: IBM Mainframe Discussion List
> > > [mailto:[email protected]] On Behalf Of venkat kulkarni
> > > Sent: Thursday, December 12, 2013 10:24 AM
> > > To: [email protected]
> > > Subject: Re: Server Pac Panel Issue
> > >
> > > Any more clue. I never faced this kind of issue and not getting
> > > solution
> > on
> > > google/manual as well.
> > >
> > >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to [email protected] with the message: INFO IBM-MAIN
> >
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to