We're having trouble with 1 lpar in a different timezone since we went with STP 
in a new zBC12.

We used to specify the timezone offset in the CLOCK00 member in parmlib, but 
now apparently that is ignored.

It seems to me we just need to select "Logical partition time offset" instead 
of "Standard time of day" in the "General" frame of the "Customize image 
profiles" and use the correct offset on the "Time Offset" frame. But the 
activation fails with a complaint from the sysplex.

So do we need to specify an offset for every lpar in that sysplex? Is having a 
mixture of "Standard time of day" and some "Logical partition time offset" not 
supported?

>From the HMC help page:
With Logical partition time offset support, multiple sysplexes can each have 
their own local time reported to them from a STCK instruction if wanted. For 
instance, the Sysplex Timer or STP-only CTN can be set to GMT, one set of 
sysplex partitions could specify a Logical partition offset minus 5 hours, and 
a second set of sysplex partitions could specify a Logical partition time 
offset of minus 6 hours.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to