Ken,

In the CLOCK member, we code

STPMODE YES              
STPZONE NO               
TIMEDELTA 10             
OPERATOR NOPROMPT        
TIMEZONE W.05.00.00      

/* STPZONE                                                          */   
/*   SPECIFIES WHETHER THE SYSTEM IS TO GET THE TIME                */   
/*   ZONE CONSTANT FROM STP.                                        */   
/*   'NO' SPECIFIES THAT THE SYSTEM IS TO USE THE TIME              */   
/*   ZONE CONSTANT SPECIFIED ON THE TIMEZONE PARAMETER              */   
/*   INSTEAD OF THE STP ZONE VALUE                                  */   

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Ken Klein (TEMA TPC)
Sent: Monday, December 16, 2013 3:09 PM
To: [email protected]
Subject: timezone time offset in HMC image profile with "standard time of day" 
in same sysplex.

We're having trouble with 1 lpar in a different timezone since we went with STP 
in a new zBC12.

We used to specify the timezone offset in the CLOCK00 member in parmlib, but 
now apparently that is ignored.

It seems to me we just need to select "Logical partition time offset" instead 
of "Standard time of day" in the "General" frame of the "Customize image 
profiles" and use the correct offset on the "Time Offset" frame. But the 
activation fails with a complaint from the sysplex.

So do we need to specify an offset for every lpar in that sysplex? Is having a 
mixture of "Standard time of day" and some "Logical partition time offset" not 
supported?

>From the HMC help page:
With Logical partition time offset support, multiple sysplexes can each have 
their own local time reported to them from a STCK instruction if wanted. For 
instance, the Sysplex Timer or STP-only CTN can be set to GMT, one set of 
sysplex partitions could specify a Logical partition offset minus 5 hours, and 
a second set of sysplex partitions could specify a Logical partition time 
offset of minus 6 hours.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to