> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Gibney, Dave
>
> Zap an 0C1 into the PDS version at the MVCK. I bet you will find the module
> loaded into a different
> storage area with different attributes.
It appears from our tentative diagnosis that the "MVCK instruction" was not in
executable code, but rather was just data in the PARM passed to the program at
invocation. Thus the questions about where the system places PARM data before
transferring control to the user program.
This is a situation where Fault Analyzer was "a little too helpful" in
presenting instructions around (before) the point of failure.
-jc-
**********************************************************************
Information contained in this e-mail message and in any attachments thereto is
confidential. If you are not the intended recipient, please destroy this
message, delete any copies held on your systems, notify the sender immediately,
and refrain from using or disclosing all or any part of its content to any
other person.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN