I use OUTLIM on the individual SYSOUT= statements to force an S722. But
that can be PITA.


On Tue, Mar 11, 2014 at 1:54 PM, Barry Merrill <ba...@mxg.com> wrote:

> It appears that there is no JCL option for an individual job that
> can be enabled to cause the job to terminate when
> /*JOBPARM LINES=10
> is used and the job has produced 10,001 lines of output.
>
> I can only find references to JES2 EXIT 9 where the decision
> is made for lines exceeded.
>
> I never needed this before, but then I never completely filled
> my spool before with a runaway job.
>
> The circumvention was to point SYSOUT file to a CYL(1) disk
> file and force the B37 ABEND to get control of the job and
> to read the log messages.
>
> Barry Merrill
>
>
> Herbert W. "Barry" Merrill, PhD
> President-Programmer
> MXG Software
> Merrill Consultants
> 10717 Cromwell Drive
> Dallas, TX 75229
> ba...@mxg.com
>
> http://www.mxg.com - FAQ has Most Answers
> ad...@mxg.com      - invoices/PO/Payment
> supp...@mxg.com    - technical
> tel: 214 351 1966  - expect slow reply, use email
> fax: 214 350 3694  - prefer email, still works
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>



-- 
There is nothing more pleasant than traveling and meeting new people!
Genghis Khan

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN