Hi,

 

I have TSO verify exit in which I am enabling LLA exit CSVLLIX1 exit and
then deleting it this seems intermittently to cause a 378-14 abend

 

Below is the code 

 

*                                                                      

 *  Add LLA exit CSVLLIX1 in case module is LLA MANAGED                 

 *                                                                      

 *   LOAD PROGRAM                                                       

 *                                                                      

 *                                                                      

          LOAD EP=AAALLIX1                                              

          SLL  R1,8                      Get rid of auth code           

          SRL  R1,5                      Length is in double words      

          ST   R1,LLA_LENGTH                                            

          ST   R0,LLA_EXIT                                              

          L    R7,LLA_LENGTH Get Length                                 

 *                                                                      

 *  MOVE TO KEY 0 STORAGE                                               

 *                                                                      

          MODESET MF=(E,SUP_ON)              Athorize us                

 *                                                                      

          STORAGE OBTAIN,LENGTH=(R7),ADDR=(R6),SP=224                   

 *                                                                      

          O     R6,=X'80000000'       31 BIT AM MODE                    

          ST    R6,LLA_ADDR           Save Address                      

          LR    R1,R7                 Prime Length                      

          L     R0,LLA_EXIT                                             

          MVCL  R6,R0                 Move program                      

          L     R9,PSAAOLD-PSA(,R0)                 

ZZ       USING ASCB,R9                                                  

          L     R8,ZZ.ASCBASSB                                           

          USING ASSB,R8                                                  

          MVC   ADRSSTKN,ASSBSTKN                                        

 PRIME_JOB DS   0H                                                       

          LA    R8,JOB_NAME                                              

                                                                         

          CSVDYNEX REQUEST=ADD,                                         X

                EXITNAME=CSVLLIX1,                                      X

                STATE=ACTIVE,                                           X

                MODNAME=AAALLIX1,                                       X

                MODADDR=LLA_ADDR,                                       X

                STOKEN=ADRSSTKN,                                        X

                POS=FIRST,                                              X

                RETCODE=RETCODE,                                        X

                RSNCODE=RSNCODE,MF=(E,DYN_PARM)                          

*                                                                      

*                                                                      

*                                                                      

          L    R15,X'21C'                Get Current TCB                

          USING TCB,R15                                                 

          LA   R14,LLA_AREA                                             

          XC   LLA_AREA(LLA_LEN),LLA_AREA Clear Area                    

          MVC  LLA_PGM,AA.NAME                                          

          ST   R14,TCBUSER                                              

          MODESET MF=(E,SUP_OFF)

 

 

Later on I delete the exit and free up the storage

 

                                                                         

         CSVDYNEX REQUEST=DELETE,                                       X

                EXITNAME=CSVLLIX1,                                      X

                MODNAME=SGBLLIX1,                                       X

                FORCE=NO,                                               X

                RETCODE=RETCODE,                                        X

                RSNCODE=RSNCODE,MF=(E,DYN_PARM)                          

                                                                         

          L     R6,LLA_ADDR                                              

          L     R7,LLA_LENGTH                                            

 *                                                                       

          STORAGE RELEASE,LENGTH=(R7),ADDR=(R6),SP=224                   

                                                                         

 *        MODESET MF=(E,SUP_OFF)                                         

                                                                         

          DELETE EP=AAALLIX1                                             

 *                                                                       

 *        MODESET MF=(E,SUP_OFF)  

 

 

This the abend I get intermittently

 

The exit doesn't contain any STORAGE macros

 

 

  IEA705I ERROR DURING FREEMAIN SYS CODE = 378-14 IBMUSER ISPFPROC ISPFPR

IEA995I SYMPTOM DUMP OUTPUT                                            

SYSTEM COMPLETION CODE=378  REASON CODE=00000014                       

 TIME=03.07.19  SEQ=00039  CPU=0081  ASID=0036                         

 PSW AT TIME OF ERROR  070C1000   8149BE10  ILC 2  INTC 0D             

   NO ACTIVE MODULE FOUND                                              

   NAME=UNKNOWN                                                        

   DATA AT PSW  0149BE0A - 00181610  0A0D18CE  18FB180C                

   AR/GR 0: 008DB6C0/84000000   1: 00000000/84378000                   

         2: 00000000/008BE6FC   3: 00000000/00000003                   

         4: 00000000/008DB6C0   5: 00000000/008B79D8                   

         6: 00000000/81496E10   7: 00000000/00FBFA00                   

IEA705I 00FBFA00 008DB6C0 008FF070 00000300 00000020 0004DF78          

         8: 00000000/00000000   9: 00000000/0000001C                   

         A: 00000000/0004DF78   B: 00000000/7F5662E0                   

         C: 00000000/00000081   D: 00000000/0004C030                   

         E: 00000000/0438B5A2   F: 00000000/00000014                   

 END OF SYMPTOM DUMP                                                   

Abend 00378000 hex occurred processing authorized command 'SPSWT'.     

ISPD210  CMD abended - 'SPSWT' terminated abnormally.                  

***



----------------------------------------------------------------------