Bob

Yes they are part of linklist. Before and after IPL there extents were 2
and 4.
On 10 Aug 2014 16:25, "Bob Shannon" <[email protected]> wrote:

> > Load libraries go to more than one extent all the time. I don't believe
> there is any "general" problem.
>
> The problem occurs if the libraries are in the Linklist. A new extent
> won't be reflected in the DEB. For non-Linklist libraries it shouldn't be a
> problem until the next IPL or until a new Linklist Set is created..
>
> Bob Shannon
> Rocket Software
> ================================